Vanguard Managed Solutions PRVYS18PWA Variable Control Operation, To Turn Off Gas To Appliance

Models: PRVYS18PWA

1 32
Download 32 pages 35.25 Kb
Page 16
Image 16
VARIABLE CONTROL

VANGUARD FLAME-MAX®

UNVENTED PROPANE/LP GAS LOG HEATER

OPERATING

HEATER

Continued

VARIABLE CONTROL

OPERATION

The variable control valve can be set to any heat setting and flame height desired, by simply turning the control knob until that setting is attained. Even the lowest setting provides realistic, dancing yellow flames. Selecting higher settings produces greater heat output. This results in in- creased heating comfort.

TO TURN OFF GAS WARNING: Do not operate heater between PILOT and HIGH positions.

Shutting Off Heater CAUTION: Do not try to adjust heating levels by using the manual shutoff valve.

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1.Press in and turn control knob clock-

wise ClockwiseShutting Off Burners Only (pilot stays lit) to the HIGH position.

2.Turn the control knob clockwise ClockwiseMANUAL LIGHTING to the PILOT position.

3.Press in control knob and turn clock-

wise Clockwiseing Instructions, page 15. to the OFF Position.

Shutting Off Burners Only (pilot stays lit)

1.Turn the control knob clockwise ClockwiseTHERMOSTATICALLY- CONTROLLED MODELS to the HIGH position.

2.Press in and turn control knob clock-

wise ClockwiseFOR YOUR SAFETY to the PILOT position.

MANUAL LIGHTING

PROCEDURE

1.

Follow steps 1 through 5 under Light-

 

ing Instructions, page 15.

2.

Depress control knob and light pilot

 

with match.

3.

Keep control knob pressed in for 30

THERMOSTATICALLY- CONTROLLED MODELS

FOR YOUR SAFETY

READ BEFORE

LIGHTING

Manual background WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas sup- plier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been un- der water.

LIGHTING

INSTRUCTIONS

Manual background WARNING

If fireplace has glass doors, never operate this heater with glass doors closed. If you op- erate heater with doors closed, heat buildup inside fireplace will cause glass to burst. Also if fireplace opening has vents at the bottom, you must open the vents before operating heater.

You must operate this heater with a fireplace screen in place. Make sure fireplace screen is closed before running heater.

NOTICE: During initial operation of new heater, burning logs will give off a paper-burning smell. Orange flame will also be present. Open damper or window to vent smell. This will only last a few hours.

Note: Homeowners generally prefer to operate their heater with the chimney damper closed. This will put all the heat into the room. However there may be times you will desire the full flames of the Hi heat setting but will find the heat output excessive. You can open the chim- ney damper (if you have one) fully or partially to release some of the heat.

Manual background WARNING: Damper handle will be hot if heater has been running.

1.STOP! Read the safety information in column 2.

2.Make sure manual shutoff valve is fully open.

3. Turn control knob clockwise ClockwiseManual background to the OFF position.

seconds after lighting pilot. After 30

seconds, release control knob. Now

follow step 8, page 15.

Ignitor Button

Control Knob

LO Pilot

 

HI

 

OFF

Figure 24 - Control Knob and Ignitor Button Location

16

104343

Page 16