OPTIONAL POSITIONING OF THERMOSTAT SENSING BULB

OWNER’S MANUAL

OPTIONAL POSITIONING OF THERMOSTAT SENSING BULB

FOR MASONRY AND FACTORY-BUILT METAL FIREPLACE

If your log set cycles to pilot, but the room temperature drops to a lower than ideal comfort level before the log

5.The mounting clip must be a minimum of 3" from bottom of fireplace to pre- vent crimping of capillary. Once you have decided on a location, clean the area thoroughly. Remove the paper backing from the adhesive on back of mounting clip. Press the clip into the new location so that the thermostat sensing bulb will be positioned verti- cally with the capillary at the bottom (see Figure 34). Slide the thermostat sensing bulb into the clip.

IMPORTANT: Do not crimp capillary.

Thermostat

Sensing

Bulb

Adhesive- backed Mounting Clip

Figure 31 - Locating Thermostat Sensing Bulb on Masonry Fireplace

set comes back on, you may want to repositionthethermostatsensingbulb.

The thermostat sensing bulb is located near the gas valve assembly on the mounting bracket. This location allows the thermostat to keep the room temperature at an ideal comfort level for most fireplace applica- tions. For positioning the thermostat sens- ing bulb elsewhere, an adhesive-backed mounting clip has been provided.

Tools needed: 1/4" hex driver or socket

1.Remove logs. Locate the gas valve as- sembly and thermostat sensing bulb (see Figure 28).

2.The adhesive-backed mounting clip (see Figure 29) is attached to the ther- mostat sensing bulb. Remove the ad- hesive-backed mounting clip.

3.With 1/4" hex driver or socket, loosen the thermostat screw. Carefully slide the thermostat sensing bulb out of the retaining clamp (see Figure 30).

Note: Do not remove the screw. Make sure you tighten the screw after remov- ing the thermostat sensing bulb.

IMPORTANT: Do not force or bend the thermostat sensing bulb or capillary.

4.The thermostat sensing bulb may be located to the lower right front side of fireplace. Determine location of sens- ing bulb, but do not mount sensing bulb until step 5. If you have a masonry fire- place, see Figure 31 for location. If you have a factory-built metal fireplace, see Figure 32 for location. If your fireplace has glass doors, position sensing bulb directly behind door gap on right bot- tom side (see Figure 33).

Gas Valve Assembly

Thermostat

MountingSensing Bulb

Bracket

Figure 28 - Location of Gas Valve Assembly and Thermostat Sensing Bulb

Figure 29 - Adhesive-backed Mounting Clip

Thermostat

Capillary Screw

Retaining

Thermostat

Clamp

Sensing Bulb

Thermostat

Sensing Bulb

Adhesive- backed Mounting Clip

Figure 32 - Locating Thermostat Sensing Bulb on Factory-built Metal Fireplace

Thermostat

Sensing

Bulb

Adhesive- backed Mounting Clip

Glass Doors

Figure 33 - Installing Thermostat Sensing Bulb behind Glass Doors

 

Thermostat

 

Sensing

 

Bulb

 

Adhesive-

 

backed

 

Mounting

Capillary

Clip

 

 

Do Not Crimp

 

Capillary

Figure 34 - Positioning the Thermostat Sensing Bulb in the Vertical Position with the Capillary at the Bottom

Figure 30 - Removing Thermostat Sensing Bulb

104343

21

Page 21
Image 21
Vanguard Managed Solutions PRVYS18PWA installation manual Optional Positioning Of Thermostat Sensing Bulb