50

 

 

 

 

 

 

 

52

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

47

 

 

 

 

 

 

 

 

51

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

53

 

50

 

 

 

 

 

 

54

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

56

 

 

 

 

 

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

46

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

48

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

45

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

49

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

45

17 18 20 19

(45)The bowl arms are to be replaced in the following way:

a)Disconnect the mixer on the main switch or disconnect the connecting cable.

b)Lower the bowl arms.

c)Place the mixer on its back and remove the legs of the mixer (17) by removing the screws (18).

d)The bottom plate (19) is removed by removing the nuts (20).

e)Remove the cotter pin (51), securing the lifting bolt (46) and the lifting nut (47).

f)Remove the lifting bolt (46) and the lifting nut (47).

g)Remove the 2 circlips (48) from the 2 bowl arm guide rods (49); then the bowl arm guide rods (49) can be knocked back so that the bowl arms are free and can be removed.

(50)The lifting lever is replaced in the following way: a) Begin as described above from a) to f) inclusive.

g) Remove the crank shaft (52) by removing the circlip (56). h) Ensure that the key (53) has also been removed. i) Remove the lifting lever (50).

Adjustment of bowl height

a)Lower the bowl arms.

b)Loosen the counter nut (54) and remove the cotter pin (51).

c)Remove the lifting bolt (46) and the lifting nut (47).

d)Adjust the bowl height by turning the lifting nut (47) either out or in, on the lifting bolt (46).

e)Mount the lifting bolt with the lifting nut and the cotter pin, and tighten the counter nut (54).

f)Ensure that the measure (0) 5" is correct when the bowl is raised to normal working position, and repeat the procedure if the measure is not correct.

g)Ensure that all mixing tools are fitting in the bowl.

9

Page 12
Image 12
Varimixer J, F manual 17 18 20