Vermont Castings Seville
Assembly
You will need the following tools to assemble the Seville:
• 7/16" open end wrench | • safety glasses & gloves |
• flat head screwdriver | • power drill w/ 1/8" (3mm) bit |
• stub handle phillips screwdriver
Unpack the Stove
1.Remove the shipping straps and plastic wrap.
2.Inspect the stove and contents for shipping damage or missing parts. Immediately notify your dealer of any damage. Do not install this stove if any damage is evident or any parts are missing.
Hardware Bag contents:
•Stove Legs, 4
•Fan Switch Bracket (for use with optional fan)
•
•#10 x 1/2" sheet metal screws, qty 2
•Owner's Registration Card
•
3.Remove the Top Plate from the stove body by lifting up and away. Set it aside for replacement after the stove has been positioned and connected to the chimney.
Optional Fan Kit 2960
Install the Fan Kit within the Rear Shroud before you remove the stove body from the shipping pallet.
To test the fan operation before installation:
1.Connect the power cord to a three prong outlet.
2.Turn the rheostat switch ON.
3.Apply heat to the snapstat. The fan will operate when the snapstat reaches 90˚F.
If the Control is left in the ON position, the fan will shut off when the snapstat temperature falls below 90˚.
Install the Snapstat
1.Disconnect the leads from the Snapstat terminals.
2.Use pliers to remove the retainer ring from the Snapstat Cover and slip the cover off the wire harness. Discard cover.
3.Reconnect the wire leads to the Snapstat Plate.
4.Using two sheet metal screws from the fan kit, attach the Snapstat Plate to the Inner Shroud as indicated in Figure 19.
| Snapstat |
Rear Shroud | |
| Leads |
| Snapstat |
| Cover |
| (Discard) |
| ST464 |
Fig. 19 | Install the Snapstat. |
ST462 |
|
Fig. 20 | Install the Fan body into the Rear Shroud. |
Switch Bracket
Retainer Nut
Control Knob
Switch Box | ST463 |
Fig. 21-1 Install the rheostat switch.
14 | 30001490 |