Many building code inspectors follow these guidelines when approving installations.

Figure 9 shows one NFPA-recommended method. All combustible material in the wall is cut away a sufficient distance form the single-wall connector to provide the required 12Ó clearance for the connector. Any material used to close up the opening must be noncombustible.

Chimney

Connector

1/2Ó (13mm)

Noncombustible

Material

ST727

Fig. 9 Wall pass-through enclosed with noncombustible materials.

Three other methods are also approved by the NFPA. These are:

Using a section of double-wall chimney with a 9 inch clearance to combustibles.

Placing a chimney connector pipe inside a ventilated thimble, which is then separated from combustibles by six inches of fiberglass insulating material.

Placing a chimney connector pipe inside a section of 8 inch diameter, solid-insulated, factory-built chim- ney, with two inches of air space between the chimney section and combustibles.

In Canada, the Canadian Standards Association has established different guidelines. Figure 10 shows one method, in which all combustible material in the wall is cut away to provide the required 18Ó (450mm) clear- ance for the connector. The resulting space must remain empty. A flush-mounted sheet metal cover may be using on one side only. If covers must be used on both sides, each cover must be mounted on noncom- bustible spacers at least 1Ó (25mm) clear of the wall. Your local dealer or your local building inspector can provide details of other approved methods of passing a chimney connector through a combustible wall. In Canada, this type of installation must conform to CAN/ CSA-B365, Installation Code for Solid Fuel Burning Appliances and Equipment.

NOTE: Do not vent your Seneca into a factory-built (zero-clearance) fireplace. These appliances and their chimneys are specifically designed as a unit for use as fireplaces. It may void the listing or be hazardous to adapt them to any other use.

DO NOT CONNECT THE HEATER TO ANY AIR DISTRIBUTION DUCT OR SYSTEM.

18Ó (450mm)

 

Empty Space All

Sheet Metal

Around the

Chimney

Cover

Connector

(One side

 

only)

ST728

Fig. 10 Hollow wall pass-through.

Floor Protection

A tremendous amount of heat radiates from the bottom plate of your Seneca stove. The floor area directly under and around the stove will require protection from radiant heat as well as from stray sparks or embers that may escape the firebox.

Heat protection is provided through the use of a Dutchwest Bottom Heat Shield. Spark and ember protection must be provided by a floor protector constructed with noncombustible material as specified. Most installations will require that the bottom heat shield be attached. Only when the stove is placed on a completely noncombustible surface such as unpainted concrete over earth may it be used without the heat shield.

Even when the bottom heat shield is installed, you must provide special protection to the floor beneath. For installation with the heat shield attached, use a noncombustible floor protector such as 1/4" non- asbestos mineral board or equivalent, or 24 gauge sheet metal. The floor protector may be covered with a decorative noncombustible material if desired. Do not obstruct the space under the heater.

Protection requirements vary somewhat between the United States and Canada as follows:

8

2006063

Page 8
Image 8
Vermont Casting 2170 manual Floor Protection, Wall pass-through enclosed with noncombustible materials

2170 specifications

The Vermont Casting 2170 is a remarkable wood stove that combines classic styling with modern efficiency, making it a favored choice for homeowners looking to enhance their heating options. Renowned for its performance, this wood stove stands out due to its unique blend of traditional craftsmanship and innovative technology.

One of the primary features of the Vermont Casting 2170 is its robust construction. Made from high-quality cast iron, the stove not only ensures durability but also efficient heat retention. This material allows the stove to radiate warmth long after the fire has died down, offering prolonged comfort during the coldest months. With a striking design that includes elegant arches and detailed accents, the 2170 serves as a functional art piece in any living space.

The heating capacity of the Vermont Casting 2170 is impressive, boasting an output of up to 75,000 BTUs, which can effectively heat large areas up to 2,100 square feet. This makes it suitable for both smaller homes and larger spaces needing efficient heating solutions. Its large firebox can accommodate larger logs, enabling longer burn times and reducing the frequency of loading during the evening.

Another notable feature is its advanced air intake system, which promotes efficient combustion. This system not only optimizes fuel consumption but also minimizes emissions, making the 2170 an environmentally friendly choice. Additionally, it features a secondary combustion system, ensuring that burning gases are consumed for maximum heat and minimal waste.

The Vermont Casting 2170 also incorporates a convenient, easy-to-use ash pan, allowing users to clean out ash without hassle, contributing to a more streamlined maintenance experience. With an adjustable air control mechanism, users can easily regulate the burn rate, ensuring the perfect balance between heat output and fuel efficiency.

Overall, the Vermont Casting 2170 exemplifies a perfect fusion of vintage aesthetics and contemporary technology. Its durable construction, substantial heating capacity, and environmentally conscious features make it a top choice among wood stoves, creating a warm, inviting atmosphere while also being kind to the planet. For anyone looking to invest in a wood stove that combines style, functionality, and sustainability, the Vermont Casting 2170 is a compelling option that stands the test of time.