Stove and Chimney Connector Clearance Charts
Model 2477 Small Convection Heater
| UNPROTECTED SURFACES | PROTECTED SURFACES | ||||||||
|
|
|
|
|
|
|
|
|
| |
|
|
|
| Corner |
|
|
|
| Corner |
|
| Parallel Installations | Installations | Parallel Installations |
| Installations | |||||
Stove Clearance | Side |
| Rear3 | Corner | Side |
| Rear3 |
| Corner | |
No heat shields | (A) 23” |
| (B) 24” | (C) 19¹⁄₂” | (D) 7” |
| (E) 19” |
| (F) 15¹⁄₂” | |
| (584 mm) |
| (610 mm) | (495 mm) | (178 mm) |
| (483 mm) |
| (394 mm) | |
Rear exit, | (G) 20” |
| (H) 13” | N/A | N/A |
| N/A |
| N/A | |
flue collar heat shields | (508 mm) |
| (330 mm) |
|
|
|
|
|
|
|
Top exit1,2, flue collar | (K) 16” |
| (L) 14” | (M) 11¹⁄₂” | (N) 7” |
| (O) 11” |
| (P) 9” | |
(406 mm) |
| (356 mm) | (292 mm) | (178 mm) |
| (279 mm) |
| (229 mm) | ||
w/connector heat shield | Right Side |
|
|
| Right Side |
|
|
|
|
|
and right side heat shield | Only |
|
|
| Only |
|
|
|
|
|
Top exit1 , flue collar | (K) 23” |
| (L) 15” | (M) 12¹⁄₂” | (N) 9” |
| (O) 15” |
| (P) 12¹⁄₂” | |
heat shield, | (584 mm) |
| (381 mm) | (318 mm) | (229 mm) |
| (381 mm) |
| (318 mm) | |
Double wall connector |
|
|
|
|
|
|
|
|
|
|
Chimney Connector Clearance: |
|
|
|
|
|
|
|
|
| |
|
| 19¹⁄₂” |
|
|
| 14¹⁄₂” |
|
| ||
No connector heat shield |
|
| (495 mm) |
|
|
| (368 mm) |
|
| |
|
| 9¹⁄₂” |
|
|
| 6¹⁄₂” |
|
| ||
w/connector heat shield |
|
| (241 mm) |
|
|
| (165 mm) |
|
| |
& flue collar heat shield |
|
|
|
|
|
|
|
|
|
|
|
| 10¹⁄₂” |
|
|
| 10¹⁄₂” |
|
| ||
& flue collar heat shield |
|
| (267 mm) |
|
|
| (267 mm) |
|
| |
Front Clearance to Combustibles: | (All Installations) |
| 48” (1219 mm) |
|
|
1.Shielding for a top exit stove must include a flue collar shield to protect the area behind the flue collar.
2.Chimney connector heat shields must extend exactly 24” (610 mm) above the flue collar of the stove.
3.Dimension is to the top plate of the stove, not the back wall of the stove.
Important:
When choosing an installation utilizing the side loading door located on the left side of the stove, follow the minimum dimensions given in the Stove and Chimney Connector Chart on Page 14 and the Minimum Dimen- sions for Noncombustible Floor Protectors given on Page 9, Figure 12.
For operation of the side loading door, the minimum clearances on the left side of the stove for usable opera- tion is 13” (330 mm) in a corner installation and 18” (457 mm) in a parallel installation.
14 | 30002314 |