Dutchwest
Distance from Center of Flue Collar to Wall in
Dutchwest Convection Heater Model 2477
NOTE: These are not clearance distances. These measurements indicate where the centerline of the flue col- lar will be for various installations. Measurements are from the centerline of the flue collar to the wall, not the wall protector.
B A C
C
E | D |
F |
F |
ST427
| UNPROTECTED SURFACES | PROTECTED SURFACES |
| ||||
|
|
| Corner |
|
| Corner |
|
| Parallel Installations | Installations | Parallel Installations | Installations |
| ||
Chimney Connector | Side | Rear | Corner | Side | Rear | Corner |
|
Listed, Approved | (A) 35” | (B) 13” | (C) 19⁵⁄₈” | (D) 21” | (E) 13” | (F) 19⁵⁄₈” |
|
(889 mm) | (330 mm) | (499 mm) | (533 mm) | (330 mm) | (499 mm) |
| |
flue collar shield |
|
|
|
|
|
|
|
Single wall, with | (A) 28” | (B) 12” | (C) 18⁵⁄₈” | (D) 19” | (E) 9” | (F) 16¹⁄₈” |
|
Connector heat shields | (711 mm) | (305 mm) | (473 mm) | (483 mm) | (229 mm) | (410 mm) |
|
and flue collar shield |
|
|
|
|
|
|
|
Single wall with no | (A) 35” | (B) 22” | (C) 26⁵⁄₈” | (D) 19” | (E) 17” | (F) 22⁵⁄₈” |
|
heat shields | (889 mm) | (559 mm) | (676 mm) | (483 mm) | (432 mm) | (575 mm) |
|
|
|
|
|
|
|
|
|