Vermont Casting 2477 Dutchwest Non-CatalyticConvection Heater, Dutchwest Convection Heater Model

Models: 2477

1 32
Download 32 pages 24.83 Kb
Page 15
Image 15
Dutchwest Convection Heater Model 2477

Dutchwest Non-Catalytic Convection Heater

Distance from Center of Flue Collar to Wall in Top-Exit Installations

Dutchwest Convection Heater Model 2477

NOTE: These are not clearance distances. These measurements indicate where the centerline of the flue col- lar will be for various installations. Measurements are from the centerline of the flue collar to the wall, not the wall protector.

B Manual background A Manual backgroundC

C

E

D

F

F

ST427

 

UNPROTECTED SURFACES

PROTECTED SURFACES

 

 

 

 

Corner

 

 

Corner

 

 

Parallel Installations

Installations

Parallel Installations

Installations

 

Chimney Connector

Side

Rear

Corner

Side

Rear

Corner

 

Listed, Approved

(A) 35”

(B) 13”

(C) 19⁵⁄

(D) 21”

(E) 13”

(F) 19⁵⁄

 

Double-wall, with

(889 mm)

(330 mm)

(499 mm)

(533 mm)

(330 mm)

(499 mm)

 

flue collar shield

 

 

 

 

 

 

 

Single wall, with

(A) 28”

(B) 12”

(C) 18⁵⁄

(D) 19”

(E) 9”

(F) 16¹⁄

 

Connector heat shields

(711 mm)

(305 mm)

(473 mm)

(483 mm)

(229 mm)

(410 mm)

 

and flue collar shield

 

 

 

 

 

 

 

Single wall with no

(A) 35”

(B) 22”

(C) 26⁵⁄

(D) 19”

(E) 17”

(F) 22⁵⁄

 

heat shields

(889 mm)

(559 mm)

(676 mm)

(483 mm)

(432 mm)

(575 mm)

 

 

 

 

 

 

 

 

 

30002314

15

Page 15
Image 15
Vermont Casting 2477 manual Dutchwest Non-CatalyticConvection Heater, Dutchwest Convection Heater Model, 30002314