Dutchwest
Distance from Center of Flue Collar to Wall in
Dutchwest Convection Heater Model 2478
NOTE: These are not clearance distances. These measurements indicate where the centerline of the flue col- lar will be for various installations. Measurements are from the centerline of the flue collar to the wall, not the wall protector.
B A C
C
E | D |
F |
F |
ST427
| UNPROTECTED SURFACES | PROTECTED SURFACES |
| ||||
|
|
| Corner |
|
| Corner |
|
| Parallel Installations | Installations | Parallel Installations | Installations |
| ||
Chimney Connector | Side | Rear | Corner | Side | Rear | Corner |
|
Listed, Approved | (A) 30” | (B) 13” | (C) 18¹⁄₂” | (D) 21” | (E) 12¹⁄₂” | (F) 18” |
|
(762 mm) | (330 mm) | (470 mm) | (533 mm) | (318 mm) | (457 mm) |
| |
flue collar shield |
|
|
|
|
|
|
|
Single wall, with | (A) 27” | (B) 13” | (C) 18¹⁄₂” | (D) 20” | (E) 9” | (F) 15” |
|
Connector heat shields | (686 mm) | (330 mm) | (470 mm) | (508 mm) | (229 mm) | (381 mm) |
|
and flue collar shield |
|
|
|
|
|
|
|
Single wall with no | (A) 33” | (B) 23” | (C) 26¹⁄₂” | (D) 20” | (E) 17” | (F) 21¹⁄₂” |
|
heat shields | (838 mm) | (584 mm) | (673 mm) | (508 mm) | (432 mm) | (546 mm) |
|
|
|
|
|
|
|
|
|
14 | 30002278 |