Contents
BFC36
DO NOT DISCARD THIS MANUAL Retain for future use
Homeowner’s Installation and Operating Manual
Balance Flue Closed Combustion
Safety Information
Table of Contents
Precautions
BFC36 Balance Flue Heat-CirculatingFireplace
BFC36 Balanced Flue Heat-CirculatingFireplace
B C A
BFC36 Balance Flue Heat-CirculatingFireplace
7412647
BFC36 Balance Flue Heat-CirculatingFireplace
7412647
Fig. 2 Fireplace and chase parts identification
Chimney Requirements - Offset Installations
30˚ Elbow Offsets
Illustration Key
BFC36 Balance Flue Heat-CirculatingFireplace
Planning Information
Mounting the Fireplace
Planning the Chimney Run
The Ten Foot Rule
Installation
Chase Installation
Chimney Supports
Insulating Fireplace Enclosure for Cold Climates
Installing Electrical Wire
Straight-UpChimney Installation
Framing
Chimney Set-up
Offset Installation
Ceiling Chimney Hole Possible Obstructions
Cutting the Hole
Framing the Ceiling Hole
Positioning, Safety Strips Securing the Fireplace
BFC36 Balance Flue Heat-CirculatingFireplace
7412647
Installing the Chimney System
Installing the Firestop Spacer
Proper Firestop Spacer Installation
in the Ceiling Hole
Continue Installing Pipe to Complete Run
Install Remainder of Chimney Sections
Canadian Requirements for Insulation Shield
Additional Ceilings
Installing Top Housing or Termination
Installing Chimney in a Chase
Air Space Clearances
Finishing
BFC36 Balance Flue Heat-CirculatingFireplace
7412647
Side View
Hearth Installation
Minimum Hearth Extension Dimensions
Side Wall Protection
Minimum Wall Clearances
Install Door Handles
COMMON MATERIALS AND FACTORS
Example for Common Brick
BFC36 Balance Flue Heat-CirculatingFireplace
Installing Line for Gas Logs
Finish Glass Doors
Glass Door Operation
BFC36 Balance Flue Heat-CirculatingFireplace
Install 1/2” 13mm certified gas pipe through opening. After gas pipe installation is complete, use insulation that was removed from gas line tube to repack space around the pipe. Material should be inserted from
BFC36 Balance Flue Heat-CirculatingFireplace
7412647
BFC Balanced Flue Fireplace
BFC36 Balance Flue Heat-CirculatingFireplace
Description
BFC36
BFC Balanced Flue Fireplace continued
BFC36 Balance Flue Heat-CirculatingFireplace
7412647
Accessories
Hearth Extension Insulation
Provides hearth extension floor protection
EH2416
Chimney Components
Component
Description
Model Number
LIMITED WARRANTY & 30 YEAR PROTECTION PLAN
7412647
B. Firegrate, Glass Doors, Outside Air System
C. Fan Motor