BFC36 Balance Flue Heat-Circulating Fireplace

Planning Information

Preplanning an installation is very important to ensure safety and to save time and money. An installer must predetermine where a fireplace will be set and how the chimney system will be run.

Mounting the Fireplace

A fireplace may only be mounted on the following sur- faces:

1.A flat combustible surface.

2.A raised wooden platform.

3.A concrete block or other solid object placed be- neath each of the four (4) corners of the fireplace.

The fireplace must be spaced 1” (25mm) from a com- bustible back wall and 1/2” (13mm) from a combustible side wall or support. (Page 13, Fig. 17)

Planning the Chimney Run

LTOTAL INSTALLED

T TRIPLE LENGTH LENGTH

 

 

 

 

WALL

(LT)

(L1)

 

 

 

L

 

1

81

�����"

�����"

 

 

 

 

818

�����"

�����"

 

 

 

L

 

1

83

�����"

�����"

 

 

 

84

�����"

�����"

 

FP288a

Fig. 4 Installed lengths of chimney sections.

Determine how the chimney will be run, length of run and chimney components required to complete the job. (Fig. 4) Never install a chimney below minimum heights.

In planning a chimney system, it is important to know:

1.The height of a chimney is measured from the hearth to the exit point on the termination.

2.A chimney cannot be offset more than 30° from a vertical plane.

3.A chimney may run straight up or it may be neces- sary to offset it to avoid obstructions.

4.The maximum length of an angled run (total chimney system) is 20’ (6m).

5.No more than 2 offsets (4 total 30° elbows in U.S./or 2 total 45° elbows in Canada) per fireplace may be used.

6.A guy wire stabilizer is required for chimneys extend- ing more than 6’ (1.8m) above a roof line.

The Ten Foot Rule

Major U.S. building codes specify a minimum chimney height above the roof top. The “Ten Foot Rule” is a fire safety rule and not a draft rule. To ensure proper draft, it is recommended that you always meet or exceed the “Ten Foot Rule,” especially when installing a termination on a high pitch roof. (Fig. 5)

The key points of the “Ten Foot Rule” are:

1.If the horizontal distance from the chimney to the peak of the roof is 10’ (3m) or less, the top of the chimney must be at least 2’ (610mm) above the peak of the roof, but never less than 3’ (914mm) in height above the highest point where it passes through the roof.

2.If a horizontal distance from the chimney to the peak of the roof is more than 10’ (3m), a chimney height reference point is established on the surface of the roof a distance of 10’ (3m) from the chimney in a horizontal plane. The top of the chimney must be at least 2’ (610mm) above the reference point, but never less than 3’ (914mm) in height above the high- est point where it passes through the roof.

 

0 To 10'

 

 

2' Min. 3'

0 To 10'

 

Min.

 

 

 

2' Min. 3'

 

 

Min.

 

Reference

 

 

Point

 

 

 

AC246

Fig. 5

Ten Foot Rule illustration.

 

6

7412647

Page 6
Image 6
Vermont Casting BFC36 manual Planning Information, Mounting the Fireplace, Planning the Chimney Run, Ten Foot Rule

BFC36 specifications

The Vermont Castings BFC36 is a wood-burning fireplace that stands out for its impressive craftsmanship, aesthetics, and efficiency. This versatile model seamlessly combines traditional craftsmanship with modern technology, making it a popular choice for homeowners seeking both functionality and style.

One of the most notable features of the BFC36 is its ability to generate substantial heat while maintaining an energy-efficient performance. With a heating capacity of up to 2,200 square feet, it is perfect for large living spaces or open-concept homes. The unit is designed with a high-efficiency combustion system that allows for longer burn times and reduced wood consumption, making it an environmentally responsible choice. This efficiency not only translates into less frequent refueling but also leads to lower heating costs over time.

The BFC36 also boasts a large viewing area, framed by a beautifully crafted cast-iron faceplate. The door features a ceramic glass window that provides an unobstructed view of the flames, enhancing the ambiance of any room. The unit's elegant design is sure to become a focal point in your living space, combining functionality with a classic aesthetic.

A standout technology featured in the BFC36 is its Advanced Secondary Combustion System. This innovative feature ensures that any unburnt gases are reintroduced into the firebox, where they are burned off, resulting in cleaner emissions and more efficient heat output. This technology not only reduces smoke and particulate emissions but also enhances the fireplace's overall performance.

The BFC36 is constructed from durable cast iron, known for its superior heat retention and distribution capabilities. This material not only ensures longevity and resilience but also provides a traditional look that pairs well with various home styles. The fireplace is also equipped with an air wash system that keeps the glass clean, allowing for unobstructed views of the flames and a hassle-free maintenance experience.

In terms of installation, the BFC36 is designed to accommodate both masonry and zero-clearance installations, making it highly versatile for various home designs. Additionally, it offers customizable options, including multiple finish colors and trim styles, which enables homeowners to tailor the appliance to their specific tastes and preferences.

In conclusion, the Vermont Castings BFC36 is an exemplary wood-burning fireplace that emphasizes efficiency, beauty, and modern technology, making it an ideal choice for anyone looking to enhance their home's heating solution while maintaining an inviting atmosphere.