Vermont Casting ANSI Z83.7-2000 Dyna-GloPropane Forced Air Construction Heaters, Specifications

Models: ANSI Z83.7-2000 CSA 2.14-2000

1 14
Download 14 pages 40.55 Kb
Page 3
Image 3

Dyna-Glo Propane Forced Air Construction Heaters

The heater is designed and approved for use as a construction heater under ANSI Z83.7., CSA2.14 It is hard to anticipate every use which may be made of this heater. CHECK WITH YOUR LOCAL

FIRE SAFETY AUTHORITY IF YOU HAVE QUESTIONS ABOUT APPLICATIONS.

Other standards govern the use of fuel gases and heat producing products in specific applications. Your local authority can advise you about these.

IMPORTANT: Read this user's manual carefully and completely before trying to operate or service this heater. Improper use of this heater can cause serious injury or death from fire, explosion and carbon monoxide poisoning.

This is a direct-fired forced-air construction heater for either indoor or outdoor use. Its intended use is primarily the temporary heating of buildings or structures under construction, alteration or repair. All the products of combustion generated by the heater are forced through the heater and released into the area being heated. This heater operates at approximately 98%+ combustion efficiency but still produces a small amount of carbon monoxide. Humans can tolerate small amounts of carbon monoxide for short periods. Carbon monoxide can build up in a heated space and failure to provide adequate ventilation could result in poisoning or death.

ΦWARNING: Not for use with ductwork.

SPECIFICATIONS:

Model No.

 

RMC-FA40DLX

-

RMC-FA100DLX

RMC-FA150DLX

 

RMC-FA40A

RMC-FA(50A)

RMC-FA100A

RMC-FA150A

 

 

Input Rating

40,000 Btu/hr

30,000 Btu/hr

70,000 Btu/hr

120,000 Btu/hr

-

50,000 Btu/hr

100,000 Btu/hr

150,000 Btu/hr

 

 

Type of Gas

Propane

Propane

Propane

Propane

Gas Supply Pressures

 

 

 

 

to Regulator Maximum Cylinder Pressure

Cylinder Pressure

Cylinder Pressure

Cylinder Pressure

Minimum (for purpose

5psig

5psig

5psig

5psig

of Input Adjustment)

 

 

 

 

Manifold Pressure

11” W.C.

10” W.C.

9.5” W.C

8” W.C.

Gas Consumption

1.9lbs/hr

2.3lbs/hr

4.6lbs/hr

7lbs/hr

3.3lbs/hr

1.4lbs/h

3.3lbs/h - 5.6lbs/hr

5.6lbs/hr

 

 

Electrical Input

120V, 60Hz, 1 Ø

120V, 60Hz, 1 Ø

120V, 60Hz, 1 Ø

120V, 60Hz, 1 Ø

Amperage

Unload

0.35A

0.58A

0.6A

0.6A

Load

0.63A

0.75A

0.8A

0.8A

Fan

Unload

3550rpm

3570rpm

3580rpm

3580rpm

Load

3000rpm

3300rpm

3300rpm

3300rpm

 

Ignition

 

Piezo/Manual Spark

Continuous Spark

Continuous Spark

Continuous Spark

Spark Gap

 

0.16”

0.16”

0.16”

0.16”

Size (L x W x H)

18.1” x 7.7” x 12.8”

18.1” x 7.7” x 12.8”

25.12” x 9” x 15.5”

25.12” x 9” x 15.5”

Weight

 

15.2lbs (6.9kg)

15.2lbs (6.9kg)

22.7lbs (10.3kg)

22.7lbs (10.3kg)

Page 2

Page 3
Image 3
Vermont Casting ANSI Z83.7-2000, CSA 2.14-2000 Dyna-GloPropane Forced Air Construction Heaters, Specifications