Vermont Castings EWF30
Operation |
|
Attach Handles | Primary Air Control |
The fallaway handle is used to open and close the front | Damper |
| |
doors. Remove after each use so the handle will not get |
|
hot. Keep in convenient location for each use. (Fig. 26) |
|
Assemble the primary air control and damper handles by passing the screw through the wood shaft and into the bright metal hub. Tighten carefully until snug. Do not
overtighten. Wood handle could crack. (Fig. 27)
Steel Handle
Fallaway
Handle
FP1570
Fig. 28 EWF30 controls.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| The primary air control is located in the upper left | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| corner of the unit. (Fig. 26) It is the primary source of | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| FP1568 | air | for starting, maintaining, and reviving the fire. | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| handle stub. |
|
| |||||
Fig. 26 Insert fallaway handle into door | Generally, more air entering the fireplace makes the fire | |||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| burn hotter and faster, while less air prolongs the burn. | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Metal Hub | The air supply is open to the maximum when the control | ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| lever is pushed down, and closed when pulled up. To | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| vary the burn rate, adjust the control to the desired posi- | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| tion in between these extremes; opening the primary air | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Wood Shaft | control makes the unit burn hotter. Closing the control | ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| slows the unit down. You may adjust to any position you | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| desire. |
Screw | The Damper | |
| The damper directs air flow within the fireplace. | |
FP1569 | The damper is operated by moving the lever located in | |
| ||
Fig. 27 Assemble primary air control and damper handles. | the upper right corner of the unit. It has two positions: | |
(Damper handle shown) | Open to start or revive the fire and closed, for normal | |
EWF30 Controls | operation and to control burn rate. The damper is open | |
when the lever is pulled out and closed when pushed in. | ||
Three controls regulate the performance of the EWF30 | There are no intermediate settings for the damper. | |
NOTE: Always open the damper before opening the | ||
fireplace: A primary air control supplies oxygen for the | ||
fire, the damper directs air flow within the fireplace and | doors. Close damper to set burn rate. | |
a |
| |
warm air flow into the room. (Fig. 28) |
|
Primary Air Control
A single air control regulates the amount of heat the fire will produce and how long it will burn.
18 | 20008662 |