Installing the Chimney System

Vermont Castings EWF30

provided). Continue attaching the ducting together using three (3) screws at each joint until you have installed sufficient duct to arrive at your duct termina- tion location.

3.At the termination end, install the duct termination. This should be installed from the outside of the home. Cut a hole in the desired location approxi- mately 4¹⁄₂” in diameter, caulk around the hole, and slide the termination through the opening from out- side the home. The termination/rain cap should be caulked around its perimeter to assure a tight seal. The rain cap opening should be positioned down- ward. (Fig. 14)

The AK-MST Outside Air Kit is now installed and ready for use.

Caulking

Duct Termination

Rain Cap

Wall

FP1061

Fig. 14 Caulk and install duct termination/rain cap in place.

Installing the Chimney System

Start by attaching the first chimney section to the collar on top of the fireplace.

Install the pipe as pictured in Figure 15. When you get a good lock, you will hear the pipe clearly snap together. Once sections are snap-locked in place, it is extremely difficult to get them apart. Make sure the pipe is firmly snapped and locked together as each pipe section is mounted.

When installing elbows, only outer pipe will snap- lock. Middle pipes simply slide into position. Be sure to always attach straps on upper elbow to a structural framing member. (Fig. 16)

Continue installing the pipe as required until pipe is installed up through the ceiling. At this point, you must install a firestop spacer.

Pipe Section

Pipe

Rim

Installing the Firestop Spacer Hem

in the Ceiling Hole Lance

Pipe

Hem

FP1566

Fig. 15 Install pipe, listening for the snap-lock to fasten.

Elbow Strap

Support Structure

 

Elbow Strap

 

(must be tight)

 

Ceiling Hole

 

Framing

Angled Strap

 

 

Angled Firestop

FP270/271

Chimney Support Strap

 

(must be tight)

Fig. 16 Attach straps to a structural framing member.

Installing the Firestop Spacer

in the Ceiling Hole

A firestop spacer is used to keep pipe spaced properly and required for safety.

Nail the firestop spacer (at each corner) to the framing members of the ceiling hole. NOTE: A firestop spacer is not required at the roof.

Hole sizes listed in Figure 9 for angled firestop spacers provide minimum required air space to chimney pipe for ceiling thickness up to 8” (203mm). When combined thickness of ceiling material, ceiling joists and flooring material exceeds 8” (203mm), adjustments must be made in framing to assure that minimum air spaces to chimney are maintained.

Proper Firestop Spacer Installation

Figure 17 shows different installation procedures for both an area that is an attic and an area that is not an attic.