Vermont Casting TBREF36NH Finishing, Locating your Electric Fireplace, Clearance to Combustibles

Models: TBREF36 TBREF36NH

1 16
Download 16 pages 17.45 Kb
Page 6
Image 6
Finishing

TBREF Electric Fireplace

Nail side-nailing flange

FP549

Fig. 3 Adjustable drywall strip (nailing flange).

Finishing

CAUTION: All joints between the finished wall and the appliance surround (top and

sides) may be sealed only with noncom- bustible material. Only noncombustible material can be applied as facing to

the appliance surround (the black painted face).

When finishing the appliance, never obstruct or modify the air inlet/outlet grilles in any manner.

NOTE:Finish the wall with the material of

your choice. Refer to Figures 2a and 2b for specific clearances when installing a combustible mantel or other combustible projection.

Locating your Electric Fireplace

Your new fireplace may be installed into an existing masonry or zero-clearance fireplace. It may also be in- stalled using a prefabricated cabinet available from your dealer, or be built into a wall.

When choosing a location for your new fireplace, en- sure that the general instructions are followed. Also, for best effect, install the fireplace out of direct sunlight.

 

Clearance to Combustibles

Sides

......................................................... 0" (0 mm)

Floor

0" (0 mm)

Top

0" (0 mm)

Hearth

A hearth is not mandatory; however, for aesthetic pur- poses, we recommend use of a noncombustible hearth that does not obstruct the air openings.

Cold Climate Installation: To conform to applicable insulation codes, it is manda- tory the outer walls be insulated when installing this unit against a non-insulated exterior wall or chase.

Cabinet Installations

Cabinets are available from your dealer which allow fast, convenient installation of your fireplace against existing walls.

Main Power Wall Switch Wiring

To reduce the risk of fire, electrical shock, and personal injury, before attempting maintenance or service, disconnect all power to the fireplace

at the main service panel.

120 Volt Wall Switch Wiring Installation

A qualified electrician must perform any electrical wiring of this appliance. For Ca-

nadian installations, wiring must be done in accordance with local codes, and/or the current CSA C22.1 Canadian Electrical Code. For U.S.A. installations, wiring must be done in accordance with the National Electrical Code ANSI/NFPA No. 70.

NOTE: For 120 Volt installations, use a single-pole, single-throw, 20 Amp-rated wall switch.

Wiring of the wall switch must be completed prior to installing the unit.

Connect the wall-mounted switch to the fireplace by running grounded 2-conductor wire (Min. 14 AWG) to the switch from the junction box on the side of the unit.

1.Locate the voltage selection switch under the logset on the left front corner of the unit.

2.Ensure the switch is in the 120 Volt position.

3.Loosen the screws securing the junction box cover, and remove the cover.

4.Remove knockouts in the box cover to use a cable clamp.

5.Pull out two (2) wires: black and white.

6.Connect the hot wire (black) from the wall switch to the L1 (black) wire on the unit, and the other wire from the wall switch to the L1 (black) wire on the power supply.

7.Connect the white wire from the unit to the neutral (white) wire on the power supply.