Viking F20533 EN manual Leveling/Adjustments/Alignments Anti-tip Device Installation

Models: F20533 EN

1 16
Download 16 pages 3.84 Kb
Page 12
Image 12

Leveling/Adjustments/Alignments (cont.)

7

Anti-tip Device Installation (cont.)

3

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set the high corner of range so that the top of side trim is 3/8” (0.95 cm) above countertop. Level range to high corner.

Mark and drill holes where bracket will be located.

Attach bracket with

 

mounting hardware provided.

Anti-tip Device Installation

WARNING

Tipping hazard.

To reduce the risk of property damage or personal injury; install anti-tipping device provided in accordance with the installation instructions in this document. Device must be engaged properly to prevent product from tipping over.

1

Measure

ment(A )

Measure from floor to bottom

of the anti-tip opening located on the back of range.

This will be measurement (A).

Connecting Gas & Electric

DANGER

Gas leak hazard.

To avoid risk of personal injury or death; leak testing of the appliance must be conducted

according to the manufacturer’s instructions. Before placing appliance in operation, always check for gas leaks with soapy water solution.

• DO NOT USE AN OPEN FLAME TO CHECK FOR GAS LEAKS.

Note: Refer to electrical and gas requirements section for proper installation information.

2

X

 

 

 

 

 

 

 

 

 

nt

(A

)

 

 

 

 

 

 

 

 

e

 

 

 

 

 

 

 

 

m

)

 

 

 

 

 

 

e

.3

cm

 

 

ea

sur

(1

 

 

 

M

 

2

 

 

 

 

 

 

+

1/

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Locate anti-tip bracket on rear wall with the top left corner at

measurement (A) plus 1/2” (1.3 cm) from the floor and 3-5/8” (9.2 cm) from where the right side of range (facing range) is to be located.

Range

“X”

Width

Dimension

30”

3-5/8” (9.2 cm)

36”

8” (20.3 cm)

48”

5” (12.7 cm)

 

 

60”

5” (12.7 cm)

Anti-tip location for each range width.

1

Connect gas and electrical.Before placing appliance in operation, always check for gas leaks. This must be performed by your dealer,a qualified licensed plumber,or gas service company.

22

23

Page 12
Image 12
Viking F20533 EN manual Leveling/Adjustments/Alignments Anti-tip Device Installation, Connecting Gas & Electric