VGBQ530-4RT/E

T-Series/E-Series
Four-Burner All-Grill

VGBQ532-3RT/E

T-Series/E-Series
Three-Burner Grill
w/Side Burners

VGIQ530-4RT/E

T-Series/E-Series
Four-Burner All-Grill
(inc. TruSear™Burner)

VGIQ532-3RT/E

T-Series/E-Series
Three-Burner Grill
w/Side Burners
(inc. TruSear™Burner)
GAS
Fixedpiping installations
• Check withlocal gas utility
companyor with local codes
forinstructions on installing gas
supplylines. All gas
connectionsshould be made
bya competent technician and
inaccordance with local codes
andor ordinances. Inthe
absenceof codes, the
installationmust comply with
theNational Fuel Gas Code
ANSIZ223.1.
• An installer-suppliedgas shut-
offvalve must be installed in an
easilyaccessible location. All
installer-suppliedpartsmust
conformto local codes.
• Must be isolatedfrom the gas
supplypiping system by closing
itsindividual manual shut-off
valveduring any pressure
testingof that system at test
pressuresequal to or less than
1/2psi (3.5 kPa).
Naturalgas models
• Watercolumn pressure
oOperating pressure—4.0”
WCP
oSupply pressureof 6” – 14”
WCP
oIf incoming pressureexceeds
14”WCP,a step-down
regulatoris required.
• Acceptsstandard residential
1/2”(1.3 cm) ID gas service
line;1/2” (1.3 cm) NPT male
with7/8” (2.2 cm) flare adapter.
oIf using a Viking GSH12
flexiblehose, remove the
1/2”(1.3 cm) flare adapter
andattach hose to the 7/8”
(2.2cm) male flare on the
regulatorassembly.
LP/propanemodels
• Watercolumn pressure
oOperating pressure—10”
WCP
oSupply pressure of 11” – 14”
WCP(for fixed piping
installations)
oIf incoming pressure exceeds
14”WCP, a step-down
regulatoris required.
• Acceptsstandard residential
1/2”(1.3 cm) ID gas service
line;1/2” (1.3 cm) NPT male
with3/8” (0.95) flare adapter.
LP/propanetank installations
• Watercolumn pressure
oOperating pressure—10”
WCP
• Includeshigh-capacity
hose/regulatorassembly for
connectionto a standard 5-
gal./20-lb.(approx. 12”
diameter/18”H.)LP/propane
gascylinder equipped with a
Type1, QCC-1 connector
oThe cylinder connection
device must be compatible
withthe Type 1, QCC-1
connectoron the outdoor
cookingappliance.
oThe cylinder must be
providedwith a shut-off valve
terminatingin an LP/propane
gassupply cylinder valve
outletspecified.
oThe cylinder supply system
mustbe arranged for vapor
withdrawaland provided with
alisted OPD (overfilling
preventiondevice).
ELECTRICAL
T-Seriesmodels
o9-volt DC battery for
electronicignition (not
included?)
o2’ (61.0 cm) power cord
supplycord with 3-prong
groundedplug attached to
rotisserie
120VAC/60 Hz
oRotisserie motor max. amp
usage—6.0
E-Seriesmodels
o3’ (91.4 cm) power cord
supplycord with 3-prong
groundedplug attached to
grill
120VAC/60 Hz
oGrill max. amp usage—3.0
o2’ (61.0 cm) power cord
supplycord with 3-prong
groundedplug attached to
rotisserie
120VAC/60 Hz
oRotisserie motor max. amp
usage—6.0
PLUMBING
• Not applicable
PLANNING AND DESIGN GUIDE
VIKINGRANGE.COM • 1-888-VIKING1
REL E A S E D 05/ 1 2 / 0 8
©20 0 7 VRC — INFORMATION SUBJECTTOCHANGE
OUTD OOR—CO OKIN G

53”W. Ul tra-Pre mium T-S erie s/E- Series Ga s Gril l

UTILI TY

REQUIREMENTS
Installation Requirements
VGBQ530-4RT/E VGBQ532-3RT/E VGIQ530-4RT/E VGIQ532-3RT/E
Burnerrating
StandardSS grill burners (each)
25,000BTU (7.3 kW) Nat./22,500 BTU (6.5 kW) LP
Smokerburner (split standard) 12,500BTU (3.7 kW) Nat./10,500 BTU (3.1 kW) LP
GourmetGlo™rotisserie burner 15,000BTU (4.4 kW) Nat./13,500 BTU (4.0 kW) LP
Sidegrill burners (each) 15,000BTU (4.4 kW) Nat./ 15,000BTU (4.4 kW) Nat./
13,500BTU (4.0 kW) LP 13,500BTU (4.0 kW) LP
TruSearinfrared burner
3
0,000BTU (8.8 kW) Nat./LP
3
0,000BTU (8.8 kW) Nat./LP