INSTALL THE ROUGH-IN PLATE
1.Run 10" round steel ductwork, from exterior blower to the installation location. For best performance, use the straightest possible duct run and the few- est number of elbows. Tape all joints.
2.Run 120 VAC electrical power cable from service panel and from remote blower to installation loca- tion.
3.Remove wiring box cover. Remove knockouts from the wiring box. Feed 6" of power cable through openings and attach cables to wiring box with appropriate connectors.
|
| GREEN | WIRING BOX |
|
|
| GREEN | LINE IN | |
| GREEN | WHITE | ||
EXTERIOR | WHITE |
| BLACK | 120 VAC |
| 60 HZ | |||
BLOWER | BLACK |
|
| |
|
| 10 A MAX. | ||
|
|
|
| |
|
|
| BLACK |
|
| BLACK |
| WHITE |
|
| WHITE |
| GREEN |
|
|
|
| ||
|
| |||
|
|
|
4.Wire black to black, white to white, and green or bare wire beneath green ground screw. Replace wiring box cover.
5.Attach
6.Connect ductwork to
10" DAMPER
MOUNTS INSIDE DUCTWORK AT LEAST 3" ABOVE CANOPY OUTLET
10" ROUND
DUCT
HOUSE
WIRING
WIRE
BOX
POWER COVER
CABLE
7. Turn on power and check blower operation.
VIKING RANGE CORPORATION
GREENWOOD, MISSISSIPPI 38930 USA
USE AND CARE
Disconnect electrical power supply and lock out service panel before cleaning or servicing this unit.
CLEANING
Remove cover and carefully vacuum blower and inside of housing. Be careful not to bend or otherwise damage blower wheel.
MOTOR LUBRICATION
The motor is permanently lubricated. Do not oil or disassemble motor.
4 | 99043131E |
|