Vinotemp WM25-85SFCD Pressure, Superheat and Subcooling Readings, Valve Operation, Complaint

Models: VINO2500SSD WM250-850SCU WM25-85SFCD VINO8500SSD VINO4500SSD VINO6500SSD

1 8
Download 8 pages 62.11 Kb
Page 3
Image 3
5. Pressure, Superheat and Subcooling Readings

5. Pressure, Superheat and Subcooling Readings

NOTES: THE VALVES MUST BE IN THE MIDDLE POSITIONS TO READ PROPERLY.

 

Complaint

 

 

Possible Causes

 

a.

High suction pressure and low head pressure

a.

Compressor may be bad

 

b.

High suction pressure and low head pressure

b.

Expansion valve opened, too

 

Low superheat and low subcooling

 

much oil

 

 

 

 

c.

High suction pressure and high head pressure

c.

Overcharge

 

 

 

 

 

Low superheat and high subcooling

d.

Non-condensable gas

 

d.

High to normal suction pressure and high head pressure

 

 

Low subcooling

e.

Air

restricted,

dirty

condenser,

e.

High suction pressure and high head pressure

 

Low subcooling

 

bad condenser fans

 

 

f.

High suction pressure and high head pressure

f.

High

room

temperature,

high

 

High superheat

 

evaporator load

 

 

 

g.

Low suction pressure and low head pressure

g.

Undercharge

 

 

 

 

 

High superheat and low subcooling

h.

Liquid

line

 

restricted

after

h.

Low suction pressure and low to normal head pressure

 

 

High superheat and high subcooling

 

receiver,

solenoid

valve

 

 

 

restricted

 

 

 

 

i.

Low suction pressure and low head pressure

i.

Suction line restricted

 

 

Low subcooling

j.

Air

restricted

at

evaporator,

j.

Low suction pressure and low head pressure

 

Low superheat and low subcooling

 

evaporator iced

 

 

 

k.

Low suction pressure and low to normal head pressure

k.

Evaporator restricted

 

 

 

High superheat and normal to high subcooling

l.

Expansion valve restricted

 

l.

Low suction pressure and normal head pressure

 

 

High superheat and normal subcooling

m. Both evaporator and condenser

m. Low suction pressure and high head pressure

 

High superheat and high subcooling

 

restricted

 

 

 

 

n.

Low suction pressure and high head pressure

n.

Liquid

line

restricted before

 

High superheat and high subcooling

 

receiver

 

 

 

 

o. low to normal suction pressure and high head pressure

o.

Condenser restricted

 

 

 

High to normal superheat and high subcooling

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6. Valve Operation

SPINDLE BACK POSITION SPINDLE FRONT POSITION SPINDLE MIDDLE POSITION

Fig. 2.1 Valve Operation

- 2 -

Page 3
Image 3
Vinotemp WM25-85SFCD manual Pressure, Superheat and Subcooling Readings, 1 Valve Operation, Complaint, Possible Causes