Manuals
/
Vinotemp
/
Kitchen Appliance
/
Refrigerator
Vinotemp
WM-65SFCH, VINO6500SSH, WM-85SFCH 7 VINO8500SSH Electrical Wiring Diagram VTSTAT, UJ6220Z
Models:
VINO2500SSH
WM-25SFCH
WM-45SFCH
WM-65SFCH
WM-850SCU
WM-85SFCH
VINO8500SSH
VINO4500SSH
VINO6500SSH
1
14
26
26
Download
26 pages
8.41 Kb
11
12
13
14
15
16
17
18
<
>
Troubleshooting
Install
Warranty
Electrical Wiring
Humidity Adjustment
Temperature Setting
Coil Cleaning
Safety
Feature Description
Page 14
Image 14
Fig. 2.7 VINO8500SSH Electrical Wiring Diagram (VTSTAT, UJ6220Z)
Fig. 2.8 VINO8500SSH Wiring Diagram (DIGITAL CONTROLLER, UJ6220Z)
- 13 -
Page 13
Page 15
Page 14
Image 14
Page 13
Page 15
Contents
READ AND SAVE THESE INSTRUCTIONS
VINO2500SSH, 4500SSH VINO6500SSH, 8500SSH
WINE-MATE Split System Installation, Operation & Care Manual
Vinotemp International Corp
Installer’s Instruction…………….…..….……..……………..7
TABLE OF CONTENTS
Feature Description…………………………….……………..3
Temperature Control & Humidity Adjustment.………….15
A DEDICATED 20 AMP CIRCUIT IS HIGHLY RECOMMENDED
Important Safety Information
DO NOT USE A GROUND FAULT INTERRUPTER GFI
Feature Description
Fig. 1.1 WM25-85SFCH Evaporator Unit
Fig. 1.2 WM250-450SCU Condensing Unit
Fig. 1.3 WM650-850SCU Condensing Unit
Cellar Construction
Fig. 2.1 SSH Split System Installation
Installer’s Instruction
installed by an EPA certified refrigeration technician
Federal law requires that WINE-MATE split cooling systems be
3. Air Sensor
1. Condensing Unit
2. Evaporator Unit
4. Refrigeration Piping and Charging
MODEL
5. Pressure, Superheat and Subcooling Readings
NOTES THE VALVES MUST BE IN THE MIDDLE POSITIONS TO READ PROPERLY
REFRIGERATION
Back Position Process and manometer port closed for normal operation
6. Valve Operation
Fig. 2.2 Valve Operation
Front Position Main connection to liquid or suction line closed
Fig. 2.4 VINO2500 & 4500SSH Wiring Diagram DIGITAL CONTROLLER
7. Electrical Wiring
Fig. 2.3 VINO2500 & 4500SSH Electrical Wiring Diagram VTSTAT
Fig. 2.5 VINO6500SSH Electrical Wiring Diagram VTSTAT
Fig. 2.6 VINO6500SSH Electrical Wiring Diagram DIGITAL CONTROLLER
Fig. 2.7 VINO8500SSH Electrical Wiring Diagram VTSTAT, UJ6220Z
Fig. 2.8 VINO8500SSH Wiring Diagram DIGITAL CONTROLLER, UJ6220Z
8. Use of the adjustable low pressure control if applicable
Fig. 2.9 Adjustable Low Pressure Control
9. Condensing Unit Troubleshooting Unit not running
Temperature Control & Humidity Adjustment
1. Temperature Setting
4 Compressor safety function
Dip-switch description See detail in VSTAT instruction
3 Defrost management and setting
1 Set Point
3. Use of the Digital Controller
Fig. 3.3 Digital Controller
5 LED & Display Messages
1 Display
3.2 How to change the set-point
2 Alarm Signals 2.1 Code Description 2.2 Alarm Recovery
3 Temperature Set-Point 3.1 How to see the set-point
6 Defrost Cycle
4 Humidity Adjustment
5 Regulation Differential
7 Manual Defrost
2. Moisture Removing
1. Coil Cleaning
Care Guide
Complaint
User’s Troubleshooting
Troubleshooting Chart
Possible Causes
7.Evaporator
5.Unit running
too long or
icing
Vinotemp International 17631 South Susana Road Rancho Dominguez, CA
Customer Support
If you still have problems, please contact us at
Tel 310 Fax 310 Email info@vinotemp.com
Service under Warranty
Warranty
1. Limited Warranty
Thank you for choosing a Vinotemp cooling unit
2. Limitation of Implied Warranty
VINOTEMP SHALL NOT BE LIABLE FOR