Troubleshooting
Install
3 VINO2500 & 4500SSH Electrical Wiring Diagram VTSTAT
Warranty
If you still have problems, please contact us at
Do Not Use A Ground Fault Interrupter Gfi
Alarm Signals 2.1 Code Description 2.2 Alarm Recovery
Temperature Control & Humidity Adjustment
Defrost management and setting
Coil Cleaning
Page 3
Image 3
Important Safety Information
•
DO NOT USE A GROUND FAULT INTERRUPTER (GFI).
•
A DEDICATED 20 AMP CIRCUIT IS HIGHLY RECOMMENDED.
-
2 -
Page 2
Page 4
Page 3
Image 3
Page 2
Page 4
Contents
Vinotemp International Corp
VINO2500SSH, 4500SSH VINO6500SSH, 8500SSH
WINE-MATE Split System Installation, Operation & Care Manual
READ AND SAVE THESE INSTRUCTIONS
Temperature Control & Humidity Adjustment.………….15
TABLE OF CONTENTS
Feature Description…………………………….……………..3
Installer’s Instruction…………….…..….……..……………..7
Important Safety Information
DO NOT USE A GROUND FAULT INTERRUPTER GFI
A DEDICATED 20 AMP CIRCUIT IS HIGHLY RECOMMENDED
Feature Description
Fig. 1.2 WM250-450SCU Condensing Unit
Fig. 1.1 WM25-85SFCH Evaporator Unit
Fig. 1.3 WM650-850SCU Condensing Unit
Cellar Construction
Federal law requires that WINE-MATE split cooling systems be
Installer’s Instruction
installed by an EPA certified refrigeration technician
Fig. 2.1 SSH Split System Installation
4. Refrigeration Piping and Charging
1. Condensing Unit
2. Evaporator Unit
3. Air Sensor
REFRIGERATION
5. Pressure, Superheat and Subcooling Readings
NOTES THE VALVES MUST BE IN THE MIDDLE POSITIONS TO READ PROPERLY
MODEL
Front Position Main connection to liquid or suction line closed
6. Valve Operation
Fig. 2.2 Valve Operation
Back Position Process and manometer port closed for normal operation
7. Electrical Wiring
Fig. 2.3 VINO2500 & 4500SSH Electrical Wiring Diagram VTSTAT
Fig. 2.4 VINO2500 & 4500SSH Wiring Diagram DIGITAL CONTROLLER
Fig. 2.6 VINO6500SSH Electrical Wiring Diagram DIGITAL CONTROLLER
Fig. 2.5 VINO6500SSH Electrical Wiring Diagram VTSTAT
Fig. 2.8 VINO8500SSH Wiring Diagram DIGITAL CONTROLLER, UJ6220Z
Fig. 2.7 VINO8500SSH Electrical Wiring Diagram VTSTAT, UJ6220Z
Fig. 2.9 Adjustable Low Pressure Control
9. Condensing Unit Troubleshooting Unit not running
8. Use of the adjustable low pressure control if applicable
1. Temperature Setting
Temperature Control & Humidity Adjustment
1 Set Point
Dip-switch description See detail in VSTAT instruction
3 Defrost management and setting
4 Compressor safety function
1 Display
Fig. 3.3 Digital Controller
5 LED & Display Messages
3. Use of the Digital Controller
2 Alarm Signals 2.1 Code Description 2.2 Alarm Recovery
3 Temperature Set-Point 3.1 How to see the set-point
3.2 How to change the set-point
7 Manual Defrost
4 Humidity Adjustment
5 Regulation Differential
6 Defrost Cycle
1. Coil Cleaning
Care Guide
2. Moisture Removing
3.Temperature
User’s Troubleshooting
Troubleshooting Chart
2.Temperature
icing
5.Unit running
too long or
7.Evaporator
Tel 310 Fax 310 Email info@vinotemp.com