Vita Spa L100 owner manual Di A Gno St Ic & Troubl E Shoot Ing, Page

Models: L100

1 48
Download 48 pages 1.02 Kb
Page 37
Image 37
DI A GNO ST IC & TROUBL E SHOOT ING

DI A GNO ST IC & TROUBL E SHOOT ING

SYMPTOM

ME A NIN G

AC T I O N

Spa Inoperative

Power failure outside of spa.

Check power source Breaker and GFCI;

 

 

Reset breaker/GFCI. Call Electrician if it

 

 

will not start.

Spa Side Inoperative

Spa Side could be locked.

If lock icon is visible, unlock by depressing the “UP” button for 5 seconds

IF ANY ERRORS ARE FOUND, THE FOLLOW ING MESSAG ES MAY BE DISPLAY E D :

MESSAGE

 

 

BLO

Blower Error

Check fuse 3 and then verify that the

 

 

blower motor is plugged in.

CP

HEET pump may be faulty.

Check that HEET pump is plugged in.

FLO

Lack of Flow:Heater disabled

Remove filter. If “FLO” disappears, clean

 

 

f i l t e r.

CS

Current Sensor

Check that current sensor board is plugged

 

 

into circuit board.

F1 or F2

Blown Fu s e

Replace fuse 1 or fuse 2

HC

Heater Error

Replace heater

HP

High Vo l t a g e

High power (voltage) observed. Check

 

 

power connections and rerun diagnostic

 

 

t e s t

LB

Light Error

Replace underwater light bulb

LP

Low Vo l t a g e

Low Power (voltage) observed. Check

 

 

power connections and rerun diagnostic

 

 

t e s t

O3U

Ozonator Error

Replace oz o n a t o r

P1

Pump 1 Error

Check plug for Pump 1

P2

Pump 2 Error

Check plug for Pump 2

Pb

Spaside Communication

Check topside connection and remote

 

 

panel connections to power board.

PS

Pressure Switch Error

Replace Pressure Switch

SS

Heater Sensor

Replace Sensor

LS

Water Sensor

Replace Sensor

 

 

 

 

PAGE 33

 

 

 

 

Page 37
Image 37
Vita Spa L100 owner manual Di A Gno St Ic & Troubl E Shoot Ing, Page