DI A GNO ST IC & TROUBL E SHOOT ING
SYMPTOM | ME A NIN G | AC T I O N |
Spa Inoperative | Power failure outside of spa. | Check power source Breaker and GFCI; |
|
| Reset breaker/GFCI. Call Electrician if it |
|
| will not start. |
Spa Side Inoperative | Spa Side could be locked. |
If lock icon is visible, unlock by depressing the “UP” button for 5 seconds
IF ANY ERRORS ARE FOUND, THE FOLLOW ING MESSAG ES MAY BE DISPLAY E D :
MESSAGE |
|
|
BLO | Blower Error | Check fuse 3 and then verify that the |
|
| blower motor is plugged in. |
CP | HEET pump may be faulty. | Check that HEET pump is plugged in. |
FLO | Lack of Flow:Heater disabled | Remove filter. If “FLO” disappears, clean |
|
| f i l t e r. |
CS | Current Sensor | Check that current sensor board is plugged |
|
| into circuit board. |
F1 or F2 | Blown Fu s e | Replace fuse 1 or fuse 2 |
HC | Heater Error | Replace heater |
HP | High Vo l t a g e | High power (voltage) observed. Check |
|
| power connections and rerun diagnostic |
|
| t e s t |
LB | Light Error | Replace underwater light bulb |
LP | Low Vo l t a g e | Low Power (voltage) observed. Check |
|
| power connections and rerun diagnostic |
|
| t e s t |
O3U | Ozonator Error | Replace oz o n a t o r |
P1 | Pump 1 Error | Check plug for Pump 1 |
P2 | Pump 2 Error | Check plug for Pump 2 |
Pb | Spaside Communication | Check topside connection and remote |
|
| panel connections to power board. |
PS | Pressure Switch Error | Replace Pressure Switch |
SS | Heater Sensor | Replace Sensor |
LS | Water Sensor | Replace Sensor |
|
|
|