VIVOTEK
The following message is displayed when attempting to upload an incorrect file format.
Export language file: Click to export language strings. VIVOTEK provides nine languages: English, Deutsch, Español, Français, Italiano, 日本語, Português, 簡体中文, and 繁體中文.
Update custom language file: Click Browse… and specify your own custom language file to upload.
Export configuration file: Click to export all parameters for the device and
Update configuration file: Click Browse… to update a configuration file. Please note that the model and firmware version of the device should be the same as the configuration file. If you have set up a fixed IP or other special settings for your device, it is not suggested to update a configuration file.
Export server staus report: Click to export the current server status report, such as time, logs, parameters, process status, memory status, file system status, network status, kernel message ... and so on.
Tips:
•If a firmware upgrade is accidentally disrupted, say, by a power outage, you still have a last resort method to restore normal operation. See the following for how to bring the camera back to work:
Applicable scenario:
(a)Power disconnected during firmware upgrade.
(b)Unknown reason causing abnormal LED status, and a Restore cannot recover normal working condition.
You can use the following methods to activate the camera with its backup firmware:
(a)Press and hold down the reset button for at least one minute.
(b)Power on the camera until the Red LED blinks rapidly.
(c)After boot up, the firmware should return to the previous version before the camera hanged. (The procedure should take 5 to 10 minutes, longer than the normal
42 - User's Manual