VIVOTEK
180 - User's Manual
trigger boot,
di,
motion,
seq,
recnotify,
tampering,
vi,
volalarm
boot 6/6 Indicate the trigger condition:
“boot” = System boot
“di”= Digital input
“motion” = Video motion detection
“seq” = Periodic condition
“visignal” = Video input signal loss.
“recnotify” = Recording notification.
“tampering” = Tamper detection.
“vi”= Virtual input (Manual trigger)
“volalarm”= Audio detection
triggerstatus String[40] trigger 6/6 The status for event trigger
exttriggerstatus trigger,
normal~trigger
,
trigger~norma
l
<blank> 6/6 The status for event DI 1 trigger
exttriggerstatus1 trigger,
normal~trigger
,
trigger~norma
l
<blank> 6/6 The status for event audio detection
profiletrigger
di <integer> 1 6/6 Indicate the source id of di trigger.
This field is required when trigger
condition is “di”.
One bit represents one digital input. The
LSB indicates DI 0.
mdwin <integer> 0 6/6 Indicate the source window id of motion
detection.
This field is required when trigger
condition is “md”.
One bit represents one window.
The LSB indicates the 1st window.
For example, to detect the 1st and 3rd
windows, set mdwin as 5.
mdwin0 <integer> 0 6/6 Similar to mdwin. The parameter takes
effect when profile 1 of motion detection
is enabled.