Group: uart
Name Value Security
(get/set) Description
ptzdrivers_i
<0~19, 127>_
name string[40] 1/4 The name of the PTZ driver
ptzdrivers_i<0~
19, 127>_
location string[128] 1/4 The full path of the PTZ driver
enablehttptunnel <boolean> 4/4 Enable HTTP tunnel channel to control UART
Group:uart_i<0~(n-1)> n is uart port count
Name Value Security
(get/set) Description
baudrate
110
300
600
1200
2400
3600
4800
7200
9600
19200
38400
57600
115200
4/4
Set baud rate of COM port
110 => 110
300 => 300
600 => 600
1200 => 1200
2400 => 2400
3600 => 3600
4800 => 4800
7200 => 7200
9600 => 9600
19200 => 19200
38400 => 38400
57600 => 57600
115200 => 115200
databit
5
6
7
8
4/4
Data bits in a character frame
5 => 5
6 => 6
7 => 7
8 => 8
paritybit
none
odd
even 4/4
For error checking
none => none
odd => odd
even => eve
stopbit 1
24/4 1 => 1
2 => 2
uartmode rs485
rs232 4/4 rs485 or rs232
customdrvcmd_i
<0~9> string[128] 1/4 PTZ command for custom camera
speedlink_i
<0~4>_name string[40] 1/4 Additional PTZ command name
speedlink_i
<0~4>_cmd string[128] 1/4 Additional PTZ command list
ptzdriver 0~19
127 (custom)
128 (no driver) 4/4 Which PTZ driver is used by this COM port
Group: privacymask_c<0~(n-1)> for n channel product