Zhone Technologies Z-PLEX-10-24-DOC-SC Alphabetical Reference Error messages, Queryhalarm

Models: Z-PLEX-10-24-DOC-SC

1 101
Download 101 pages 3.06 Kb
Page 89
Image 89

Alphabetical Reference

Error messages

QUERYHALARM

Displays a list of history alarms.

REBOOT

Reboots the system.

TFTPDLD

This command initiates a TFTP download. It prompts for the IP address of the server, the code bank to download the image to, and the filename of the software image.

A.3 Error messages

Table A-3describes the error messages.

 

Table A-3. Error messages

 

 

Message

Explanation

 

 

FDL mgmt not supported

Tried to activate FDL on WAN 2. Only WAN 1 supports IP over

on this wan

FDL.

 

 

Invalid instance number.

Invalid index for a static route.

Valid range is 1-16

 

 

 

Invalid Loopback

Loopback activated while another loop back (either local or remote)

 

is active.

 

 

Invalid MTU size valid

Invalid MTU size.

range is 128-1500

 

 

 

Invalid parameter value

Invalid parameter value in SET command.

 

 

Invalid time slot valid

Tried to assign invalid TS.

range is 1-24

 

 

 

Invalid Wan Number

Tried to enter an invalid WAN number.

 

 

IP broadcast address

User tried to assign broadcast IP address. The Z-Plex unit does not

cannot be used

support broadcast IP addresses.

 

 

Zhone Technologies / A-31

Page 89
Image 89
Zhone Technologies Z-PLEX-10-24-DOC-SC manual Alphabetical Reference Error messages, Queryhalarm, Reboot, Tftpdld