Zhone Technologies Z-PLEX-10-24-DOC-SC manual Configuring T1 interfaces

Models: Z-PLEX-10-24-DOC-SC

1 101
Download 101 pages 3.06 Kb
Page 37
Image 37

Configuring the Z-Plex

Configuring T1 interfaces

user> SET CPUCFG:IPHOST2:1:192.168.21.24

user> SET CPUCFG:IPHOST3:1:192.168.21.25

4.4Configuring T1 interfaces

The two T1 interfaces on the Z-Plex unit can be used for either voice or data, with the following restrictions:

24 voice ports are supported, and can be from either T1 line

24 data ports are supported, and must be from only one T1 line

The following example configures the first T1 interface:

1.Activate the line:

user> SET T1CFG:STATE:1:ACTV

2.Specify the type of interface (CSU or DSX):

user> SET T1CFG:TYPE:1:CSU

3.Specify the framing:

user> SET T1CFG:FRAME:1:ESF

4.Specify the encoding:

user> SET T1CFG:CODE:1:B8ZS

5.Specify the line length (for DSX interfaces) or the buildout (for CSU interfaces):

user> SET T1CFG:LINELEN:1:N15

6.Specify the clock source:

user> SET T1CFG:CLKSRC:1:WAN1

7.Specify what type of standard FDL you will use:

user> SET T1CFG:FDL:1:ANSI

Note that if you enable standard FDL, you cannot use the IP over FDL interface for management. FDL is not supported on WAN 2.

8.Enable IP over FDL (if necessary):

user> SET T1CFG:FDL_IP:1:OFF

9.Enable the DS0 management channel (if necessary):

Zhone Technologies / 4-7

Page 37
Image 37
Zhone Technologies Z-PLEX-10-24-DOC-SC manual Configuring the Z-Plex Configuring T1 interfaces