Zhone Technologies Z-PLEX-10-24-DOC-SC manual Schan, Ses, Slip, State

Models: Z-PLEX-10-24-DOC-SC

1 101
Download 101 pages 3.06 Kb
Page 77
Image 77

Alphabetical Reference

Parameter reference

SCHAN

Specifies the first T1 time slot that data from the data port will be mapped.

Configuration group: DPCFG

Syntax: (GET/SET) DPCFG:SCHAN:1:(1-24)

SES

SES (severely errored second): indicates the total number of seconds in which the bit error rate exceeded one bit per thousand (1 x 10-3).

Configuration group: MCUR, PMTOT, PMINT, FARPMCUR,FARPMTOT, FARPMINT

Syntax: GET (PMCUR, PMTOT, FARPMCUR, FARPMTOT):SES:x

Syntax: GET (PMINT, FARPMINT):SES:x:(0-95)

SLIP

SLIP: (slipped second): indicates the total number of seconds that contain one or more controlled slips. A controlled slip is the deletion or replication of a T1 or E1 frame by the receiving equipment.

Configuration group: PMCUR, PMTOT, PMINT, FARPMCUR,FARPMTOT, FARPMINT

Syntax: GET (PMCUR, PMTOT, FARPMCUR, FARPMTOT):SLIP:x

Syntax: GET (PMINT, FARPMINT):LOFC:SLIP:x:(0-95)

STATE (V.35)

State of V.35 ports. Possible values are:

ACTV

STDBY (default): Unassigned should be channels be set to STDBY.

Note that the V.35 port must be set to STDBY while you are making configuration changes to the WAN, SCHAN, or NCHAN parameters. After setting the parameters, set the STATE to

ACTIVE.

Configuration group: DPCFG

Syntax: (GET/SET) DPCFG:STATE:1:(ACTV/STDBY)

Zhone Technologies / A-19

Page 77
Image 77
Zhone Technologies Z-PLEX-10-24-DOC-SC manual Schan, Ses, Slip, State