Parameter reference

Alphabetical Reference

RTLP (FXS)

The RTLP setting controls the amount of gain or loss added to the incoming signal after it is decoded to analog. To increase the signal level, set the RTLP setting to a positive value (the larger the number, the more gain is added). To decrease the signal level, set the RTLP setting to a negative value (the more negative the number, the more the signal level is decreased).

For example, an incoming signal at -5.0dBm can be increased to -3.0 dBm by setting RTLP to +2 dB. The RTLP range is -9.0dB to 3.0dB.

Configuration group: FXSCFG

Syntax: (GET/SET) FXSCFG:RTLP:n:(-9 to 3)

RxAB (FXO)

The RxAB setting is a read-only parameter that displays the ABCD pattern for testing the receive side of the circuit. Possible values are:

00

01

10

11

Configuration group: FXOTST

Syntax: GET FXOTST:RXAB:n

RxAB (FXS)

The RxAB setting is a read-only parameter that displays the ABCD pattern for testing the receive side of the circuit. Possible values are:

Possible values are:

00

01

10

11

Configuration group: FXSTST

Syntax: GET FXSTST:RXAB:n