Parameter reference | Alphabetical Reference |
Syntax: GET PMTOT:ALLTOT:x
BERT
Activates a bit error rate test (BERT) on a T1 line. The BER test sends a data pattern and measures the bit error rate on the selected time slot. Possible values are:
•OFF (default): terminates the BER test.
•QRSS
•ALT10: sends a 10101010 pattern during the BER test.
•2047: sends a 2047 test pattern during the BER test.
Note that you cannot perform a BER test and a loopback test simultaneously.
Configuration group: T1CFG
Syntax: (GET/SET) T1CFG:BERT:X:(QRSS/ALT/2047/OFF)
See also: PATTERN, TSBERTOFF, TSBERTON
BES
BES (bursty errored second): indicates the total number of seconds with more than one and fewer than 320
Configuration group: PMCUR, PMTOT, PMINT, FARPMCUR, FARPMTOT, FARPMINT
Syntax: GET (PMCUR, PMTOT, FARPMCUR, FARPMTOT):x
Syntax: GET (PMINT,
CLK
Specifies whether the data port clock is inverted. DTE clocking usually requires a Normal setting. If synchronization problems occur, specify the clock is inverted. Possible values are:
•NORMAL (default)
•INVERTED
Configuration group: DPCFG
Syntax: (GET/SET) DPCFG:CLK:1:(NORMAL/INVERTED)