Zhone Technologies Z-PLEX-10-24-DOC-SC manual Rlsd, Rngbk, Rtlp FXO

Models: Z-PLEX-10-24-DOC-SC

1 101
Download 101 pages 3.06 Kb
Page 75
Image 75

Alphabetical Reference

Parameter reference

RLSD

The Receive Level Signal Detect (RLSD) option allows you to define whether the RLSD control lead is held ON (high) or OFF (low).

Possible values are:

ON:

OFF (default):

Configuration group: DPCFG

Syntax: (GET/SET) DPCFG:RLSD:1:(ON/OFF)

RNGBK

Specifies whether a ringback tone is generated by the system and sent towards the network. Possible values are:

OFF (default): Ringback provided by PBX or switch

ON: Ringback tones will be sent on the corresponding DS0s for the duration of ringing on the line.

Configuration group: FXSCFG

Syntax: (GET/SET) FXSCFG:RNGBK:n:(OFF, ON)

RTLP (FXO)

The Receive Transmission Level Point (RTLP) setting controls the amount of gain or attenuation added to signals after they are decoded to analog signals. To increase the signal level, set the RTLP setting to a positive number (the larger the number, the more gain is added). To decrease the signal level, set the RTLP setting to a negative number (the more negative the number, the more the signal level is decreased). For example, an incoming signal at -5 dBm can be increased to -3 dBm by setting RTLP to +2 dB.

Possible values are from -9.0dB to 3.0dB. The default is 0dB.

Configuration group: FXOCFG

Syntax: (GET/SET) FXOCFG:RTLP:n:(-9 to 3)

Zhone Technologies / A-17