ELECTRIC FRYERS - SERVICE PROCEDURES AND ADJUSTMENTS

SERVICE PROCEDURES AND ADJUSTMENTS

WARNING: HOT OIL AND PARTS CAN CAUSE BURNS. USE CARE WHEN SERVICING THE FRYER.

WARNING: CERTAIN PROCEDURES IN THIS SECTION REQUIRE ELECTRICAL TESTS OR MEASUREMENTS WHILE POWER IS APPLIED TO THE MACHINE. EXERCISE EXTREME CAUTION AT ALL TIMES. IF TEST POINTS ARE NOT EASILY ACCESSIBLE, DISCONNECT POWER, ATTACH TEST EQUIPMENT AND REAPPLY POWER TO TEST.

THERMISTOR PROBE

RESISTANCE CHART

Solid State Control

F

Resistance

 

± 10%

 

 

77

30,000 ohms

 

 

311

494 ohms

340

340 ohms

NOTE: If probe is opened or disconnected, the LED near the center of the Control Board will be on. If probe is shorted, the first high limit light will be on.

Computer Control

F

Resistance

F

Resistance

 

± 10%

 

± 10%

 

 

 

 

77

100,000 ohms

300

1394 ohms

 

 

 

 

212

5573 ohms

350

717.7 ohms

 

 

 

 

275

2004 ohms

392

434.5 ohms

TEMPERATURE CONTROL

CALIBRATION

Solid State Control

1.Shortening in tank must be to fill line.

2.Allow the oil to cool below 300￿F.

3.Place a thermometer in the center of the tank one inch below the oil surface.

4.Set the temperature control to 350￿F and turn the fryer on.

5.After the thermometer reads 350￿F, allow the temperature control to cycle three times.

6.Agitate the shortening, to eliminate any cold zones, while you record the temperatures to calculate average temperature.

7.Calculate the average temperature. Average temperature = (Temperature at "off” + temperature at "on") / 2 . (Example: (360￿+ 340￿) / 2 = 350￿F. The average temperature should be 350￿F (± 5￿F). The following steps should be taken if not.

A.Carefully loosen the set screw in the temperature control knob.

B.Rotate the knob and set the knob at the shortening temperature.

C.Tighten the set screw.

D.Allow the fryer to cycle and check for agreement with the thermometer.

8.If the above adjustments can not be obtained, check the control and temperature probe as outlined under "TEMPERATURE CONTROL TEST” and “THERMISTOR PROBE RESISTANCE CHART".

TEMPERATURE CONTROL

TEST

WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AT THE MAIN CIRCUIT BOX. THERE MAY BE TWO SEPARATE CIRCUITS. BE SURE BOTH ARE DISCONNECTED. PLACE A TAG ON THE CIRCUIT BOX INDICATING THE CIRCUIT IS BEING SERVICED.

1.Remove screws securing control panel and let panel swing down.

2.Disconnect potentiometer plug.

3.Connect ohm meter to pins 1 and 3. Meter should read 10k ohms ± 10%.

4.Connect meter to pins 1 and 2. With knob turned clockwise to the stop, the meter should read zero ohms. Slowly rotate knob counterclockwise to stop and meter should change reading from 0 up to 10k ohms. Check that there are no dead spots and that wiper tracks smoothly as you rotate knob.

5.Connect meter to pins 3 and 2. With knob turned counterclockwise to the stop, the meter should read zero ohms. Slowly rotate knob clockwise to the stop and meter should change reading from 0 up to 10k ohms. Check that there are no dead spots and that wiper tracks smoothly as you rotate knob.