Vulcan-Hart ERD40 service manual Lift Assist Springs

Models: ERD40

1 92
Download 92 pages 12.55 Kb
Page 8
Image 8

ELECTRIC FRYERS - REMOVAL AND REPLACEMENT OF PARTS

6.Remove the screws that secure the high limit thermostat.

7.Remove the grommet from the element head.

8.Remove the bulb, capillary tube and the high limit thermostat from the element head.

9.Reverse procedure to install.

LIFT ASSIST SPRINGS

WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AT THE MAIN CIRCUIT BOX. THERE MAY BE TWO SEPARATE CIRCUITS. BE SURE BOTH ARE DISCONNECTED. PLACE A TAG ON THE CIRCUIT BOX INDICATING THE CIRCUIT IS BEING SERVICED.

1.Remove head cover screws.

2.Remove access cover by prying out on top edge with small screwdriver.

3.Disconnect spring(s) at bottom.

4.Lift head cover enough to access hanger mounting bolts.

NOTE: Do not bend or kink high limit capillary tube.

5.Remove hanger mounting nut and bolt.

6.Remove spacer and washers.

7.Remove hanger and spring out from bottom.

8.To install spring, insert hanger from top with notch pointing to rear of unit and spring hook opening pointing to front of unit. Hold in place while inserting spring from bottom.

9.Hook spring onto hanger. Reassemble spacer and washers onto hanger and secure with bolt and nut.

10.Reconnect spring at bottom and adjust as outlined under “LIFT ASSIST SPRING ADJUSTMENT”.

11. Install covers.

8

Page 8
Image 8
Vulcan-Hart ERD40 service manual Lift Assist Springs