MAINTENANCE
WARNING: TURN OVEN OFF AND UNPLUG POWER SUPPLY CORD BEFORE PERFORMING ANY MAINTENANCE.
The fan motor comes with sealed bearings and requires no lubrication.
If this oven is placed on casters, it should be connected to the supply piping with the proper disconnect device and restraint. If it is necessary to disconnect the restraint, first turn off the gas supply. Reconnect the restraint before turning the gas supply on and returning the oven to its original installation position.
Annually check the flue, when cool, to be sure it is free of obstructions.
REPLACING LAMPS
•Allow oven to cool.
•Remove all racks by pulling forward, lifting up and out.
•Remove the right rack support by lifting up.
•Unscrew glass dome(s) from light body.
•Replace the bulb(s).
•Reassemble glass dome(s), rack support and racks by reversing the disassembly procedure.
SERVICE AND PARTS INFORMATION
To obtain service and parts information concerning your GCO Series Oven, contact the