HIGH LIMIT

HIGH LIMIT

WARNING: SHUT OFF THE GAS BEFORE SERVICING.

1.Drain shortening from fry tank.

2.Remove wire leads from high limit, noting all connections for reassembly.

3.Remove high limit from mounting bracket.

4.Remove left burner as outlined under Burners.

5.Loosen the packing nut and the holding nut.

6. Remove the high limit bulb from the clamp.

7.Pull the high limit bulb through the underside of the fry tank and remove the high limit assembly.

8.Reverse the procedure to install. When installing the new high limit assembly, do not kink the high limit capillary. Wrap threads of packing nut with Teflon tape to prevent leakage.

THERMOPILE

WARNING: SHUT OFF THE GAS BEFORE SERVICING.

WARNING: ALL GAS JOINTS DISTURBED DURING SERVICING MUST BE CHECKED FOR LEAKS. CHECK WITH SOAP AND WATER SOLUTION (BUBBLES). DO NOT USE AN OPEN FLAME.

1.Disconnect thermopile lead wires as outlined under High Limit.

2.Remove (1) 10-24 screw and pull the pilot assembly away from the tank body.

3.Remove (2) side screws to detach the pilot from the holding bracket.

4.Remove pilot tubing from pilot.

5.Remove screws holding pilot bracket.