REMOVAL OF PILOT LIGHTER VALVE

REMOVAL OF PILOT LIGHTER VALVE

1.Follow steps 1-3 under Removal of Pilot Lighter Tube.

2.With a 12" wrench disconnect valve fitting from the pilot tube. (Figs. 11)

TUBE MOUNTING

STUD & BRKT.

VALVE

FITTING

 

 

 

 

PILOT TUBE

LIGHTER TUBE

 

HOLDING NUT

 

Figs. 11

 

 

 

 

 

 

 

 

 

3. Install new valve fitting and ferrule by reversing steps 1 and 2 above.

REMOVAL OF PILOT LIGHTER TUBE

1.With a 38" wrench remove (1) nut holding the lighter tube to the mounting bracket assembly. (See Figs. 11)

2.Pull lighter tube off of the mounting bracket stud. (See Figs. 11)

3.Pull the lighter tube (towards the center of the appliance) off the orifice hood. (See Figs. 11)

4.Reinstall new tube by reversing steps 1-3 above.

REMOVAL OF PILOT HOOD AND ORIFICE

1.Follow steps 1-3 under Replacement of Pilot Lighter Tube.

2.With a 716" wrench remove the orifice hood from the pilot valve fitting. (See Figs. 11)

— 11 —