REMOVAL OF PILOT LIGHTER VALVE
1.Follow steps
2.With a 1⁄2" wrench disconnect valve fitting from the pilot tube. (Figs. 11)
TUBE MOUNTING
STUD & BRKT.
VALVE
FITTING
|
|
|
| PILOT TUBE | |
LIGHTER TUBE | |||||
| HOLDING NUT | ||||
| Figs. 11 | ||||
|
| ||||
| |||||
|
|
| |||
|
|
|
3. Install new valve fitting and ferrule by reversing steps 1 and 2 above.
REMOVAL OF PILOT LIGHTER TUBE
1.With a 3⁄8" wrench remove (1) nut holding the lighter tube to the mounting bracket assembly. (See Figs. 11)
2.Pull lighter tube off of the mounting bracket stud. (See Figs. 11)
3.Pull the lighter tube (towards the center of the appliance) off the orifice hood. (See Figs. 11)
4.Reinstall new tube by reversing steps
REMOVAL OF PILOT HOOD AND ORIFICE
1.Follow steps
2.With a 7⁄16" wrench remove the orifice hood from the pilot valve fitting. (See Figs. 11)