GAS CONNECTION

LG SERIES GAS FRYERS

ŠLocate the fryer under a hood with adequate connection to an exhaust duct. The hood must extend 6” (15 cm) beyond fryer on both sides.

ŠClearance above the fryer should be adequate for combustion byproducts to be removed efficiently.

ŠAn 18” (46 cm) minimum clearance should be maintained between the flue vent and the filters of the hood venting system.

ŠNever make flue connections directly to the fryer.

ŠDo not obstruct the flow of the gases from the appliance. Proper air balance should be maintained in the room.

GAS CONNECTION

All gas supply connections and any pipe joint compound must be resistant to the action of propane gases.

The gas inlet is located on the lower rear of the fryer. Codes require that a gas shutoff valve be installed in the gas line ahead of the fryer.

The gas supply line must be at least the equivalent of ½” (12.7 mm) iron pipe for single units and 1-1/4” (31.75 mm) for batteries. If using the optional quick-disconnect flex hose, ¾” (19 mm) iron pipe for single units and 1-1/4” (31.75 cm) iron pipe for batteries.