The installation location must allow adequate clearances for servicing and proper operation. A minimum front clearance of 32" is required.
Do not obstruct the flow of combustion and ventilation air. Adequate clearance for air openings into the combustion chamber must be provided. Make sure there is an adequate supply of air in the room to replace air taken out by the ventilating system.
Do not permit fans to blow directly at the griddle. Wherever possible, avoid open windows next to the griddle. Avoid
INSTALLATION CODES AND STANDARDS
The griddle must be installed in accordance with:
In the United States of America:
1.State and local codes.
2.National Fuel Gas Code,
3.National Electrical Code,
In Canada:
1.Local codes.
2.
3.
4.Canadian Electrical Code, Part 2, CSA Standard C22.1 (latest edition). Copies may be obtained from The Canadian Standard Association, 178 Rexdale Blvd., Rexdale, Ontario, Canada M9W1R3.
ASSEMBLY
The griddle is shipped as a complete unit and does not require field assembly except for the supporting legs. Screw the legs into permanently fastened nuts on the four corners of the griddle bottom. Hand tighten the legs and set the griddle in place.
LEVELING
Place a carpenter's level on top of the griddle. Level the griddle front to back and side to side by turning the adjustment screw at the bottom of each leg.
— 5 —