When installed, minimum clearance from combustible construction must be 6" at the sides and 6" at the rear; minimum clearance from
The installation location must allow adequate clearances for servicing and proper operation. A minimum front clearance of 32" is required.
Do not obstruct the flow of combustion and ventilation air. Adequate clearance for air openings into the combustion chamber must be provided. Make sure there is an adequate supply of air in the room to replace air taken out by the ventilating system.
Do not permit fans to blow directly at the charbroiler. Wherever possible, avoid open windows next to the charbroiler. Avoid
INSTALLATION CODES AND STANDARDS
The charbroiler must be installed in accordance with:
In the United States of America:
1.State and local codes.
2.National Fuel Gas Code,
In Canada:
1.Local codes.
2.
3.
ASSEMBLY
The broiler is shipped as a complete unit and does not require field assembly except for the grates and radiants.
Place the radiants in their position (Fig. 1). Make sure that radiants nestle properly on front and rear supports. CAUTION: Do not drop radiants on supports.
Place the top grid grates in place with the grid bars sloping toward the front (Fig. 2), or with grid bars horizontal (facing down). When grid grates are placed sloping toward the front, the grooves on top will guide excess fat drippings into the grease trough.
— 5 —