Vulcan-Hart MG24CB Turning the Charbroiler on, Turning the Charbroiler OFF, Extended Shutdown

Models: MG24CB ML-114634

1 12
Download 12 pages 62.34 Kb
Page 9
Image 9

TURNING THE CHARBROILER ON

All burners are lit from constantly burning pilots. Turn gas valve control knobs to HI to ignite the burners.

TURNING THE CHARBROILER OFF

Turn gas valve control knobs to OFF.

Extended Shutdown

Turn gas valve control knobs to OFF. Turn the manual shutoff valve to OFF. Shut off the pilot flame by removing the pilot adjustment cap and turning the adjusting screw on the pilot shutoff valve (Fig. 3).

PILOT

ADJUSTMENT

SCREW

RED

BUTTON

PILOT SHUTOFF VALVE

Fig. 3

PL-52719

USING THE CHARBROILER

To preheat, turn gas valve control knobs to highest setting about 25-30 minutes before cooking time. After this period of preheat, grid temperatures will be in the range of 600°F for best broiling results. Then adjust the control knobs to a lower position to maintain the grid temperature between 575°F and 625°F.

Do not leave the burners on with knobs in the HI position for any extended period of time beyond the recommended preheat time or "burn-off" time (see CLEANING in this manual).

To minimize gas usage, operate only those burners needed for the cooking load.

GREASE PAN

Grease in the grease pan will not get hot enough to be ignited by the burners; however, under some use conditions, flaming particles may drop into the grease drawer and cause it to ignite. Only if your use conditions warrant, add a 1/16" deep layer of water in the grease pan to prevent this from happening.

— 9 —

Page 9
Image 9
Vulcan-Hart MG24CB Turning the Charbroiler on, Turning the Charbroiler OFF, Extended Shutdown, Using the Charbroiler