OPERATION

WARNING: THE CHARBROILER AND ITS PARTS ARE HOT. USE CARE WHEN OPERATING, CLEANING OR SERVICING THE CHARBROILER.

CONTROLS

Manual gas valves regulate gas flow to the burners to maintain set temperature.

BEFORE FIRST USE

Clean the protective metal oils from all surfaces of the charbroiler. Use a non-corrosive, grease dissolving commercial cleaner, following manufacturer's directions. Rinse thoroughly and wipe dry with a soft clean cloth. Clean all accessories. Rinse thoroughly and wipe dry.

LIGHTING INSTRUCTIONS

Lighting instructions are also inside the front panel. To access, remove four screws from the upper front panel. Lift the front panel off until it clears the drip pan handle.

To install the front panel, slide out drip pan, replace front panel, and install four screws in panel.

Lighting the Pilot

If the pilot goes out, an automatic shutoff valve turns off the gas supply to the burners. To relight the pilot, follow these procedures:

1.Turn the manual gas valves to the OFF position.

2.Turn the main shutoff valve to OFF.

3.Wait 5 minutes to allow gas which may have accumulated in the burner compartment to escape.

4.Turn the main shutoff valve ON.

5.Depress and hold in on the red button (Fig. 3) on the automatic shutoff valve while lighting the pilot burner.

6.When gas at the pilot has been running for about 45 seconds, release the red button. If the pilot does not remain lighted, repeat the above procedures, allowing more time before releasing the red reset button.

All initial pilot lighting adjustments must be performed by a qualified installation or service person.

— 8 —

Page 8
Image 8
Vulcan-Hart ML-114634, MG24CB Operation, Controls, Before First USE, Lighting Instructions, Lighting the Pilot