| TROUBLESHOOTING | |
| Uneven heating, sides |
|
|
|
|
| |
| burning |
| A. Burner valves improperly adjusted |
|
|
| B. Fluctuating gas pressure |
|
|
| C. Improperly adjusted burner |
|
|
|
|
| Too much top heat |
| A. Burner valves adjusted too high |
|
|
| B. Faulty ventilation |
|
|
| C. Overrated gas pressure |
|
|
| D. Improperly adjusted burner |
|
|
|
|
| Uneven heat side to side |
| A. Burner valves improperly adjusted |
|
|
| B. Appliance is not level side to side |
|
|
| C. Improperly adjusted burner |
|
|
|
|
| Uneven heat front to back |
| A. Appliance is not level front to back |
|
|
| B. Faulty ventilation |
|
|
| C. Improperly adjusted burner |
|
|
|
|
| Pilot outage |
| A. Pilot flame is set too low. Adjust pilot to allow for gas flow. |
|
|
| B. Obstruction in pilot orifice |
|
|
| C. Low gas pressure. |
|
|
|
|
| Yellow burner flames |
| A. Open burner shutters until flames are blue |
|
|
|
|
| Lifting burner flames |
| A. Close burner shutters until flames touch burner |
|
|
|
|
| Fluctuating gas pressure |
| A. Check for clogged vent on regulator |
|
|
|
|