OPERATION
The hotplate and its parts are hot. Use care when operating, cleaning or servicing the hotplate.
CONTROLS
There is one pilot for every two burners. The hotplate is equipped with standing, unmonitored pilots. Gas will flow from the pilots as soon as the main gas supply to the unit is turned on. See pilot lighting procedure below.
Each burner is independently controlled by an infinite heat control valve. Once the pilots are lit, turning the control knob to the ON position will light each burner. The burners will be in the full ON position when the control knobs are turned all the way to the left. The burners will be in the full OFF position when the control knobs are turned all the way to the right. See Fig 4.
OFF
Fig. 4
ON
CONTROL KNOBS
LIGHTING INSTRUCTIONS
1.See Fig 5. Turn main gas
2.Remove the front row of grates.
3.Turn main gas
4.To light burners, turn individual burner valves to the ON position.
Fig. 5
5.If burners fail to light, turn all valves and the main gas
PILOTS
- 7 -