| TROUBLESHOOTING | ||
| Burner does not come on |
| A. Problem with gas valve. (Call for service). |
|
|
|
| ||
| when the control knob is |
| B. Pilot burner not lit. |
|
| turned on |
| C. Low gas pressure. (Call for service) |
|
|
|
|
|
|
| Too much heat |
| A. Burner valves adjusted too high |
|
|
|
| B. Faulty ventilation |
|
|
|
| C. Overrated gas pressure |
|
|
|
| D. Improperly adjusted burner |
|
|
|
|
|
|
| Uneven heat side to side |
| A. Burner valves improperly adjusted |
|
|
|
| B. Appliance is not level side to side |
|
|
|
| C. Improperly adjusted burner |
|
|
|
|
|
|
| Uneven heat front to back |
| A. Appliance is not level front to back |
|
|
|
| B. Faulty ventilation |
|
|
|
| C. Improperly adjusted burner |
|
|
|
|
|
|
| Pilot burner will not stay lit |
| A. Pilot flame is set too low. Adjust pilot to allow for gas flow. |
|
|
|
| B.Obstruction in pilot orifice |
|
|
|
| C. Low gas pressure. (Call for Service). |
|
|
|
|
|
|
| Yellow burner flames |
| A. Open burner shutters until flames are blue |
|
|
|
|
|
|
| Lifting burner flames |
| A. Close burner shutters until flames touch burner |
|
|
|
|
|
|
| Fluctuating gas pressure |
| A. Check for clogged vent on regulator |
|
|
|
|
|
|
- 10 -