Managing System Alarms 173

Table 28 DS1/E1 UNI Module Alarms (continued)

 

 

 

 

Alarm

Meaning

Troubleshooting Steps

Group [n] Dup. IMA

The same group IMA ID has

ID

been received on links

 

belonging to different IMA

 

groups in the same card.

Correct link or group configuration.

Group [n] FE Abort

The far end rejects the

Symmetry

symmetry sent by the near end.

Group [n] FE

The far end reports it is not

Blocked

passing data.

ATM Forum (R-132)

 

Group [n] FE Config

The far end rejects the M value

Abort

used by the near end.

Check and correct near end symmetry. Only symmetric operation is supported in PathBuilder products.

Check and repair link facilities. Verify configuration.

Configure both ends to the same M value.

NOTE: This alarm should not occur if both ends are PathBuilder S310, S330, S600, or S700 products.

Group [n] FE Start

The far end is coming up

Up

(starting IMA).

ATM Forum (R-127)

 

Group [n] FE

The far end node is reporting

Insufficient Links

an insufficient number of links.

ATM Forum (R-131)

 

Group [n]

The near end finds not enough

Insufficient Links

available links.

ATM Forum (R-130)

This occurs when the near end

 

has completed parameter

 

negotiation with the far end,

 

but is neither passing data nor

 

blocked.

Information about far end state.

Check and repair link facilities. Verify configuration.

Check and correct any faulty IMA links. Check and correct IMA minimum links parameter.

Group [n] Lack of

The near end is idling because

Link

it does not have enough links

 

in an IMA group. This occurs

 

only after group parameters

 

are negotiated. When this

 

occurs, the “NE Insufficient

 

Links” alarm is also reported.

Take the group down, and stop passing data in all links.

Group [n] Link

Summary information alarm to

Information only.

Down

indicate one or more alarms on

 

 

this IMA group are active.

 

Group [n] Link Up

Summary informational alarm

Information only.

 

to indicate all alarms on the

 

 

IMA group are cleared.

 

Group [n] N<P

There are fewer configured

Continue passing data.

 

links than IMA links required to

 

 

make an IMA group active.

 

Group [n] No Link

The near end has lost all its

 

links in an IMA group because

 

these links have AFA, LOS, AIS,

 

OOF, LCD, or missing ICP cells.

 

This invalidates all the far end

 

identity.

(continued)

 

If one or more links comes back, re-identify the link(s) and renegotiate parameters with the far end group.