18CHAPTER 1: SYSTEM DESCRIPTION

Table 5 PathBuilder S310 System Specifications

SYSTEM SPECIFICATIONS

 

Ethernet 10 Base T

1

V.35/RS422

1

T1/E1 UNI

1

Mechanical:

 

Shelf dimensions

3.5” x 17” x 15.25” (H x W D)

19” rack mountable

Yes (with brackets)

Rack mount spacing

2 RMS

Cooling

2 fans @ 37 CRM each (deregulated 20%)

Unit weight (approx.)

15 lbs. per shelf

Shipping weight (approx.)

20 lbs. per shelf

Input power requirements

90-264 VAC, 50-60 Hz (110/220 self sensing),

 

standard grounded outlet or -42 to -60 VDC

Power consumption

60 watts typical, 100 watts max

Maximum current

1.5A @110VAC

 

0.75A @ 220VAC

 

3A @ 48VDC

Environmental:

 

Operating temperature

0°to 45° C

Storage temperature

-40° to 70°C

Humidity

95% @ +40°C (non-condensing)

Altitude

14000 ft.

Regulatory compliance

 

Safety

UL listed (1950, 3rd edition)

 

CSA 22.2

 

EN60950

 

FCC Part 68

Emissions

FCC Part 15, Class A

Homologation

Pending

STANDARDS

 

ATM Forum

UNI 3.x, T1/E1 CES 2.0, IMA, ATM DXI 1.0

ANSI

T1.403, T1.617 Annex D

TIA/EIA

EIA232, RS-449/422/423, 366

AT&T

Pubs 62411 and 54016

Frame Relay Forum

FRF.5 and FRF.8

IETF RFCs

1213, 1211, 1483, 1490, 1406, 1493, 1643

MOTHERBOARD SPECIFICATIONS

Main microprocessor

RISC

Memory usage

Flash EPROM, 8Mbytes

 

DRAM, 16Mbytes

(continued)

Page 30
Image 30
3Com S330 manual PathBuilder S310 System Specifications