Managing System Alarms 175

Table 28 DS1/E1 UNI Module Alarms (continued)

 

 

 

 

Alarm

Meaning

Troubleshooting Steps

 

 

 

Port Missing ICP

Two consecutive ICP cells

See also Loss of IMA Frame (LIF). This is

Cells

missing from the IMA frame.

a specific cause of that alarm and will

 

 

also be reported.

RFI IMA

ATM Forum (R-121)

Test Pattern Failed

Remote Failure Indication: Far end IMA Rx networking link state machines detected LOS, OOF, AIS. LCD, LIF or LODS.

An 8-bit pattern is sent to the remote node which must then echo it back on all ports. The local node checks the echoed pattern and reports an alarm if cells from one or more of the links fail to arrive. This alarm is declared on all links which do not reply or reply incorrectly.

Correct T1 or E1 facilities error.

Make sure that the same number of links are configured and enabled on both ends of the IMA configuration. Make sure that the configuration of both groups is the same. For instance, make sure that the payload scrambling setting is the same on both ends.

Yellow Alarm

OOF alarm is detected. A

 

received remote alarm

 

indication means that the far

 

end equipment has a problem

 

with the signal it is receiving

 

from the PathBuilder device.

Connect an external loopback cable to the port. If there are no alarms, the problem is elsewhere. Check for an open, short, or wiring error in the cable between the PathBuilder network interface port and your service provider's network interface unit, or the terminal equipment. An open transmit pair can cause this condition