3Com S330 manual Super user has changed a Information only By Super User

Models: S330

1 262
Download 262 pages 1.1 Kb
Page 180
Image 180

168CHAPTER 5: PATHBUILDER S330 DIAGNOSTICS AND PERFORMANCE STATISTICS

Table 26 MCPU and CTX Module (System) Alarms (continued)

Alarm

Meaning

Troubleshooting Steps

 

 

 

Queue 1 Over

The congestion threshold for

Check and correct VC connections.

Threshold

Queue 1was exceeded.

Check and adjust VI shaper values.

 

 

Check and adjust incoming traffic

 

 

volume. Check for faulty IMA links

 

 

which may reduce traffic handling for a

 

 

group.

Queue 2 Over

The congestion threshold for

Check and correct VC connections.

Threshold

Queue 2was exceeded.

Check and adjust VI shaper values.

 

 

Check and adjust incoming traffic

 

 

volume. Check for faulty IMA links

 

 

which may reduce traffic handling for a

 

 

group.

Queue 3 Over

The congestion threshold for

Check and correct VC connections.

Threshold

Queue 3 was exceeded.

Check and adjust VI shaper values.

 

 

Check and adjust incoming traffic

 

 

volume. Check for faulty IMA links

 

 

which may reduce traffic handling for a

 

 

group.

SAR Initialize Failure Problem with the SAR chip on the MCPU. MCPU SAR failed initialization.

System Clock

The system clock has reverted

Reverted

to a higher priority clock.

Replace the unit.

Information only. This alarm occurs only if the Clock Mode is set to Revertive on the System Clock Configuration menu.

System power up

System is powered up.

Information only.

Write Session Taken

A super user has changed a

Information only.

by Super User

read-only session to read-write.

 

 

 

 

Page 180
Image 180
3Com S330 manual Super user has changed a Information only By Super User