38CHAPTER 2: INSTALLATION

Figure 14 Rack Mounting Ear Configuration

19"

!

Caution:

PathBuilder S330/S310

One rack unit space

required above and below the

unit for clearance.

(mounting brackets required)

2Rows 3.5"

Step 3: Connect AC or DC Power and (optionally) the RPS System

3Support the shelf in its mounting place and attach the mounting hardware.

You connect the AC/DC power at the rear of the PathBuilder S330/S310 shelf. Table 10 outlines the specifications for the AC/DC Source.

Table 10 AC/DC Source Specifications

Input Power

90-264 VAC, 50-60Hz, standard grounded

Requirements

outlet

 

-42 to -60 VDC, Optional

 

AC: 14 AWG wire, Belden type 19364

 

DC: minimum 14 AWG wire, listed type

 

TC tray cable with three conductors

Power Consumption

60 Watts typical, 90 Watts maximum

Maximum Current

1.5 A @ 110VAC

 

0.75A @ 220VAC

 

3A @ 48VDC

 

 

To connect AC or DC power, follow these steps:

WARNING: Before handling AC/DC power leads, disconnect all power supply cords and always have a partner close by who is familiar with first aid for electrical shock.

Page 50
Image 50
3Com S330 manual Connect AC or DC Power and optionally the RPS System, To connect AC or DC power, follow these steps