170CHAPTER 5: PATHBUILDER S330 DIAGNOSTICS AND PERFORMANCE STATISTICS
Table 27 Alarms Common to Several Modules (continued)
Alarm | Meaning | Troubleshooting Steps |
Loss of Signal(LOS) Cannot detect a signal at a configured port. This alarm is applicable to DS3 UNI, E3 UNI,
Check the cable between the interface port and the service provider’s equipment/terminal equipment. Check cable connections. Check transmit and receive pairs for proper connection. Check terminating equipment. Call your service provider.
Network Card | A loopback is configured on |
Loopback | the port. Loopbacks are for |
| troubleshooting only and |
| should not be present under |
| normal operating conditions. |
Network Line | A loopback is configured on |
Loopback | the port. Loopbacks are for |
| troubleshooting only and |
| should not be present under |
| normal operating conditions. |
Out of Frame(OOF) | The configuration settings on |
| the port are not correct for the |
| line, or the port configuration |
| is correct, but the line is |
| experiencing errors that result |
| in an alarm. |
If you are not troubleshooting the port, turn off the loopback.
If you are not troubleshooting the port, turn off the loopback.
Verify that the framing format configured on the port matches the framing format on the line. Check the port’s statistics report for evidence of a bad line; bursts of LCVs could indicate a timing problem. If connected to local DS3/E3/OC3 equipment, check that equipment’s output level to make sure it is not overdriving the input.