170CHAPTER 5: PATHBUILDER S330 DIAGNOSTICS AND PERFORMANCE STATISTICS

Table 27 Alarms Common to Several Modules (continued)

Alarm

Meaning

Troubleshooting Steps

Loss of Signal(LOS) Cannot detect a signal at a configured port. This alarm is applicable to DS3 UNI, E3 UNI, OC3/STM-1 UNI, DS1 IMA UNI, and E1 IMA UNI ports.

Check the cable between the interface port and the service provider’s equipment/terminal equipment. Check cable connections. Check transmit and receive pairs for proper connection. Check terminating equipment. Call your service provider.

Network Card

A loopback is configured on

Loopback

the port. Loopbacks are for

 

troubleshooting only and

 

should not be present under

 

normal operating conditions.

Network Line

A loopback is configured on

Loopback

the port. Loopbacks are for

 

troubleshooting only and

 

should not be present under

 

normal operating conditions.

Out of Frame(OOF)

The configuration settings on

 

the port are not correct for the

 

line, or the port configuration

 

is correct, but the line is

 

experiencing errors that result

 

in an alarm.

If you are not troubleshooting the port, turn off the loopback.

If you are not troubleshooting the port, turn off the loopback.

Verify that the framing format configured on the port matches the framing format on the line. Check the port’s statistics report for evidence of a bad line; bursts of LCVs could indicate a timing problem. If connected to local DS3/E3/OC3 equipment, check that equipment’s output level to make sure it is not overdriving the input.