176CHAPTER 5: PATHBUILDER S330 DIAGNOSTICS AND PERFORMANCE STATISTICS

DSX-1/E1 CBR Module Alarms

Table 29 describes the alarms specific to DSX-1 and E1 CBR modules.

.

Table 29 DSX-1/E1 CBR Module Alarms

Alarm

Meaning

Troubleshooting Steps

Cellbus parity

Parity error on cells received

 

from cell bus.

Check VC and port configuration.

E1 Loss of CAS

E1 signaling multiframe

Check the physical connection and the

Multiframe

alignment has been lost.

carrier for configuration problems.

E1 Time Channel 16 All 1s in E1 time slot 16 for 2

Make sure both the local device and

AIS Rcv

consecutive frames.

the far end device are configured for

 

 

Time Slot 16 framing. If both devices

 

 

are correctly configured, there may be

 

 

a hardware problem in either device.

Far End E1 Loss of

The far end device has lost

CAS

Channel Associated signaling.

HP cellbus

High priority cell bus

congested

congested.

 

The cell port has been

 

configured to pass more CBR

 

traffic than it can physically

 

handle. The aggregate

 

bandwidth of the CBR

 

connections exceeds the total

 

bandwidth of the port. This

 

alarm indicates that you either

 

mistakenly oversubscribed the

 

cell port with CBR connections,

 

or more connections than

 

expected are simultaneously

 

active. When this condition

 

exists on the HP cell bus, lower

 

priority cell busses will not be

 

able to pass traffic out.

Check the E1 configuration of the far end device.

Remove high priority connections until the configured bandwidth is less than or equal to the total bandwidth on the port. If you have over-subscribed the port and all high priority devices are using the connections, turn off some devices.

LP cellbus

Low priority cell bus congested. Remove low priority connections until

congested

 

the configured bandwidth is less than

 

 

or equal to the total bandwidth on the

 

 

port. If you have over-subscribed the

 

 

port and all low priority devices are

 

 

using the connections, turn off some

 

 

devices.

MP cellbus

Medium priority cell bus

Remove medium priority connections

congested

congested.

until the configured bandwidth is less

 

 

than or equal to the total bandwidth

on the port. If you have over- subscribed the port and all medium priority devices are using the connections, turn off some devices.

Receive FIFO

Cells are being received from

Overflow

the cell bus faster than the CBR

 

can process them.

Reconfigure the CBR connection so that it has adequate bandwidth.

SAR SRAM failure SAR SRAM failure (applicable Replace the unit. to CBR)

(continued)

Page 188
Image 188